Release Notes
Description: Deploying OpenManage Server Administrator (OMSA) as a sudo user does not work on a system running SLES 11.
Resolution: Ensure that the directory for the sudo user exists in the /home directory on SLES 11, and then deploy OMSA. If the
directory does not exist under /home, create the sudo user using the useradd –m option. The –m option ensures that the
directory for the sudo user is created in /home directory.
Issue 47:
Description: If a device group is selected as a task target, the task runs on all devices in the group, including devices that were
added to the group after the task creation. [55466]
Resolution: Before the task runs, edit the task and ensure that the task target only includes the required devices.
Issue 48:
Description: While accessing OpenManage Essentials remotely as an OMESiteAdministrator, creating a remote task displays an
insufficient permission error. [61746]
Resolution: Close the web browser and open OpenManage Essentials again.
Issue 49:
Description: The Task Target page does not display all device groups for the OMESiteAdministrator. [61821]
Issue 50:
Description: A cloned task may not display all the task targets immediately after the task is cloned. [55462]
Resolution: Wait until the cloned task is displayed in both the Remote Tasks tree and the Remote Tasks grid, and then verify
the task targets.
Configuration management
Issue 1:
Description: The device configuration Inventory and Compliance tabs in the Devices Portal display inventory and
compliance information only after the corresponding tab is manually refreshed. [48567]
Issue 2:
Description: For device configuration inventory tasks, the Task Execution History displays the user who ran the task as
System. [48738]
Issue 3:
Description: If a device on which a configuration template was deployed, is deleted and then rediscovered, the last template
deployed on the device is not displayed in the Repurpose and Bare Metal Devices tab.
Issue 4:
Description: Auto deployment tasks created in OpenManage Essentials version 2.0 do not run successfully after upgrade to
version 2.0.1 or version 2.2. [61955]
Resolution: Recreate the auto deployment task after the upgrade.
Issue 5:
Description: When CMC deployment fails on the target chassis (firmware M1000e 5.x, VRTX 2.x, FX2/FX2s 1.x) due to invalid
or unsupported values in the template attributes, the status is displayed as "Unknown" instead of "Failed" in the Task
Execution History window under Details tab. [75135]
Resolution: See the description in task details to determine the issue.
Issue 6:
Description: If the deployment template is captured from a server with configurations like DELL PERC S130/S140 with Single
Disk based volumes, then the deployment of those templates on the target devices fail with “RAID Level not supported” error.
[77419]
Resolution: The deployment of single disk-based volumes is not supported by iDRAC server configuration feature. After
deploying the template, manually configure the single disk-based volumes using PERC configuration utility.
Issue 7:
Description: When the create template task is modified, junk characters are displayed in the template name which has non-
English characters. [79180]