Release Notes
Issue 50:
Description: When a server is discovered with the SNMP protocol, the RAC name of the server is not displayed in the device
tree, portals, and wizards. [64443]
Resolution: Ensure that the iDRAC of the server is discovered with the WS-Man protocol. Otherwise, the system name is
displayed in the device tree, portals, and wizards instead of the RAC name.
Issue 51:
Description: The location of a server is not displayed in the Device Summary table when the server is discovered out-of-band
with either the WS-Man or SNMP protocol. [62819]
Resolution: The location of the server is displayed in the Device Summary table only if the server has OMSA installed and is
discovered in-band. If the server is discovered out-of-band with either the WS-Man or SNMP protocol, the device location is
displayed only in the Data Center Location Information table.
Issue 52:
Description: The Service Tag is not displayed for the PowerEdge FN IOAs that were manufactured prior to February 1, 2016.
[63831]
Issue 53:
Description: For PowerEdge chassis, the Enclosure Slot Information table displays a slot as available, even though the slot
may be occupied by quarter-width sleds. [65732]
Issue 54:
Description: For Dell's 11th or earlier generation of PowerEdge blade servers, the NIC and NIC Port details are not displayed in
the VLAN configuration inventory, if the blade servers are discovered out-of-band with SNMP protocol. [69306]
Issue 55:
Description: For PowerVault MD Series storage arrays that are daisy chained, the Service Tag may not be displayed or
displayed incorrectly in the device inventory. [64070, 18069]
Issue 56:
Description: For a Dell 11th generation PowerEdge modular server having iDRAC firmware version 3.75 installed, the health
status displayed in OpenManage Essentials may not match with health status displayed in the RAC console. [61951]
Issue 57:
Description: For PowerVault MD Series storage arrays that are daisy chained, the enclosure ID displayed in the OpenManage
Essentials Firmware Information inventory does not match with the enclosure ID displayed in PowerVault Modular Disk Storage
Manager if default Enclosure ID values are changed. [67086]
Issue 58:
Description: Thin provisioned virtual disks of a PowerVault MD 38xxi storage array are displayed with REPOSITORY NAME &
current size and not the actual disk name & maximum size in the Virtual Disks inventory information. [42606]
Issue 59:
Description: For PowerVault MD 38xxi storage arrays, the health status displayed in OpenManage Essentials may not match
with the health status displayed in PowerVault Modular Disk Storage Manager. [42607]
Issue 60:
Description: The Service Tag of a PowerVault MD 38xx Series storage array displayed in OpenManage Essentials does not
match with the Service Tag displayed in PowerVault Modular Disk Storage Manager. [64059]
Issue 61:
Description: The power supply information displays zero watts during discovery of devices having ESXi 6.0 and 6.5 operating
system without OMSA. [78535]
Resolution: Discover the iDRAC of the devices having ESXi 6.0 and 6.5 operating system, or install OMSA.
Issue 62:
Description: When discovered using Ws-MAN protocol, PowerEdge C6420 servers running with firmware version 3.15.15.15 are
not classified under Modular Systems group in the device tree. [80935]
Issue 63:
Description: When Windows or Linux systems with OMSA 9.1.1 is discovered by using SNMP, the Inventory Collector Agent
version is not displayed under Data Sources. [82928]
15