Release Notes

Issue 3:
Description: For Dell EMC PowerVault MD storage arrays, OpenManage Essentials displays critical health status, even if the device
is in a warning state. [42607]
Issue 4:
Description: The model number for both Dell EMC Force10/Networking C150 and C7004 Ethernet switches is displayed as C150/
C7004 switch in the device inventory. The model number for both Dell EMC Force10/Networking C300 and C7008 Ethernet
switches is displayed as C300/C7008 switch in the device inventory. [43443]
Issue 5:
Description: OEM devices discovered using the SNMP or WS-Man protocol are classied under Modular Systems in the device
tree. [40572]
Issue 6:
Description: When a PowerEdge FX2s chassis is discovered using WS-Man protocol, the hostname of the corresponding mapped
sled is not displayed in the PCIe Slot Information table in the device inventory. [37351]
Issue 7:
Description: When a PowerEdge FM120x4 sled is discovered in-band using SSH protocol, the Embedded Device Information table
is not displayed in the device inventory. [39312]
Issue 8:
Description: When a PowerEdge FM120x4 sled is discovered using SNMP+WMI protocol, the Software Inventory Table displays
multiple entries for the iDRAC version. [39428]
Issue 9:
Description: If a device is not congured with the system contact details, the Contact Information table is not displayed in the
device inventory information. [36733]
Issue 10:
Description: If the PowerEdge RAID Controllers (PERC) in a PowerEdge VRTX chassis have dierent versions of rmware installed,
the Software Inventory Information table displays only the PERC with the main controller rmware version. [39761]
Resolution: Make sure you update the rmware version of the PERC manually in the Chassis Management Controller console.
Issue 11:
Description: Dell EMC EqualLogic FS7500 NAS device discovered using the management member IP is displayed as Unknown in the
device tree. [39618]
Resolution: Discover the Dell EMC EqualLogic FS7500 NAS device using the group manager IP.
Issue 12:
Description: If a PowerEdge VRTX chassis is discovered using SNMP protocol and NetBIOS name resolution setting, the
instrumentation (NetBIOS) name is not resolved. [27327]
Issue 13:
Description: When a monolithic Dell EMC 11th or 12th Generation PowerEdge server with iDRAC6/7 is discovered using the IPMI
protocol only (iDRAC out-of-band discovery), the overall health status of the server is not reported correctly in OpenManage
Essentials. This issue occurs due to a known limitation in iDRAC. [21599]
Resolution: Discover the server's iDRAC (out-of-band) using either WS-Man or SNMP protocol.
Issue 14:
Description: When only the EqualLogic storage array in a PowerEdge chassis is discovered, the EqualLogic storage array is not
classied under Modular SystemsPowerEdge chassisStorage in the device tree. [38654]
Resolution: Make sure that the PowerEdge chassis is also discovered.
Issue 15:
Description: Dell EMC Fibre Channel switches (modular) are classied under Network DevicesSwitches and not under Modular
Systems in the device tree. [36990]
Issue 16:
7