Release Notes

Description: Alerts are not received when the SNMP Trap service is stopped and started. To resolve the issue, restart the DSM
Essentials Network Monitor service.
Issue 6:
Description: For large number of alerts, two auto refreshes are required to show the total alerts and count on the home page. If the
alert count is large, the rst refresh fetches and shows only a subset of alerts. The second refresh displays the entire list.
Issue 7:
Description: If you edited sample alert actions in OpenManage Essentials version 1.0, you must manually clone them before
migration. Those will get overwritten with default sample actions.
Issue 8:
Description: The test trap from PowerVault MD 32xx/32xxi is received in OpenManage Essentials system with IP 0.0.0.0. This is an
expected behavior in OpenManage Essentials and any other trap listener.
Issue 9:
Description: While upgrading OpenManage Essentials from version 1.0.1 to 1.2 or above, all the existing Dell EMC Force10 traps are
deleted because OpenManage Essentials version 1.2 installs the tested and veried Dell EMC Force10 trap denitions. Also, the Dell
EMC Force10 traps from the MIB Import Utility are also removed and the severity of the traps are set as dened in OpenManage
Essentials version 1.2. After upgrading to OpenManage Essentials version 1.2, make sure that you update the associated Event view/
action lters for these Dell EMC Force10 trap denitions, because the previous OpenManage Essentials version 1.0.1 event lters may
not work after the upgrade.
Issue 10:
Description: When creating an alert action for an application launch, OpenManage Essentials system path variables which contain %
signs are not supported. Examples of unsupported variables are: %WINDIR%, %SystemRoot%, %APPDATA%, %HOMEPATH%, %PATH
%
, and so on.
Resolution: Avoid using the system path variables with % sign and use the full absolute path to the executable le.
Issue 11:
Description: SNMPv3 traps are received as "Unknown" alerts with severity for following CMC rmware versions: 5.20/5.21
(M1000E), 1.30/1.32 (FX2/FX2S), 2.20/2.22 (VRTX).
Issue 12:
Description: The Ignore Alert wizard is launched when Alert View lter is edited and disabling the Alert View lter has no impact on
the ltering of alerts. [79448]
Resolution: Delete the existing Alert View lter and create a new lter with the desired changes.
Issue 13:
Description: SNMPv3 traps are received even after the devices discovered using SNMPv3 are deleted from OpenManage
Essentials. [79441]
Resolution: Restart netmon service.
Remote Tasks
OpenManage Essentials supports iSM deployment on servers running Community Enterprise Operating System (CentOS).
Issue 1:
Description: The task targets tree is not expandable when iDRAC Service Module Deployment task is opened in view mode. [51128]
Resolution: Open the corresponding task in edit mode to view the selected targets.
Issue 2:
Description: Target selection changes made to a remote task are applied to other remote tasks, if the tasks are created in quick
succession. [49249]
Resolution: Right-click and delete the aected remote tasks, and re-create the required remote tasks.
Issue 3:
Description: While deploying iSM on servers running Linux with OMSA version 7.4 or earlier, the deployment task may display a
success message, even though the task actually failed because of dependency issues. To conrm if the task was successful or failed,
you can see the task details.[48523]