Release Notes
Table Of Contents
Resolution: For M1000e, FX2, and FX2s chassis, create and associate a new baseline with the necessary firmware version to
roll back.
Issue 65
Description: Currently, the alerts are not received by OpenManage Enterprise if the alerts are associated with the devices' IP
address. However, alerts are successfully received when associated with the device Service Tag. [106369]
Issue 66
Description: Invalid host names are displayed under the Source Name column and are also available for selection in some of
the OpenManage Enterprise tasks. [68214]
Issue 67
Description: Authentication by one-way and two-way trusts of AD users is not supported by the appliance.
Issue 68
Description: From the All Devices page, you cannot launch the iDRAC application interface with IPv6 addresses. [102153]
Issue 69
Description: When PCIe cards are mapped to the FX2/FX2s chassis, migration of identities is not supported on the sleds in the
same FX2s chassis since the FQDDs differ.
Issue 70
Description: Console Upgrade from 3.0 through NFS Share fails. Also, console Upgrade through HTTPS (internal Share) fails
when upgrading from versions 3.0 and 3.1. [114683]
Resolution: Use the online method for updating, or use the HTTPS method. Ensure that the security certificates are signed by
a trusted third-party certificate authority while using the HTTPS method of update.
Issue 71
Description: The selected target devices or device groups while creating an alert policy in OpenManage Enterprise-Tech
Release are cleared when the appliance is updated. [115698]
Resolution: After updating the appliance, edit the alert policy and select the target devices or device groups to receive the
group-specific alerts.
Issue 72
Description: After you update the appliance from OpenManage Enterprise-Tech Release, the Syslog server messages
do not retain the standard format of <timestamp><hostname>_<Alert_Message>. The alerts are displayed as
"EEMI@123_[id]":Alert_Message. [115699]
Issue 73
Description: Few alerts from the PowerEdge R240, R340, T140, T340, and R740xd2 servers are received with unknown
severity in the OpenManage Enterprise appliance. [112404]
Issue 74
Description: While programmatically deploying the OpenManage Enterprise from Linux shell, if the argument provided for
--name= in the command line begins with a "$" then the argument is ignored and appliance is deployed with the name
OPENMANAGE ENTERPRISE. [121158]
Resolution: The --name= argument, which begins with "$" in the command line must be enclosed in single quotes, for example,
--name= '$OME-VM'.
Issue 75
Description: The Severity status in the Alert log for the alerts received from the PowerVault ME4 storage arrays is being
reported as Unknown by the appliance. This defect is due to the unavailability of the precanned MIBs for the PowerVault ME4
storage arrays in the appliance console. [122657]
Issue 76
Description: After the console is upgraded, there is a delay of approximately 15 minutes in the initiation of the Post Upgrade
task by the appliance. [130142]
Issue 77
Description: When an already imported MIB is renamed and parsed through API the trap status is reported as 'Existing' instead
of 'Imported.'[111854]
Issue 78
18