Release Notes

Resolution: Discover the iDRAC of the devices having ESXi 6.0 and 6.5 operating system, or install OMSA.
Issue 3
Description: The compute nodes are not discovered or grouped automatically when a chassis is discovered. [84687]
Resolution: Include a new discovery range with IP addresses of the nodes. If this fails, delete and rediscover the chassis.
Issue 4
Description: In-band discovery of HyperV works only for users with local administrator privileges. [83440]
Resolution: To discover HyperV, use local admin credentials and WS-Man protocol.
Issue 5
Description: When a chassis is discovered, IOA switches are not correlated to the chassis in the device tree. [85839]
Issue 6
Description: Discovery of FS8600 storage appliance is not supported. [76808]
Issue 7
Description: NIC inventory not available when a device is discovered using Redfish. [76328]
Resolution: Discover the device using the WS-Man protocol, which is the default.
Issue 8
Description: When Compellent storage devices are discovered using SNMP, product image, MAC address, and management URL is not
displayed. [83979]
Tasks
Issue 1
Description: By default, all scheduled jobs are reset at 12:00 A.M. every day. For example, if a job is started at 10:00 A.M. to run after
every 10 hours, the next time the job runs is at 08:00 P.M. However, the subsequent time is not 06:00 A.M. the next day, but 12:00 A.M.
This is because the scheduler clock is reset at 12:00 A.M. every day. [81534]
Issue 2
Description: Currently, hardware logs of 14G iDRAC devices can only be collected from the Device Details page (that is, the Hardware
Log menu). [83414]
Resolution: To collect the hardware logs of 12G and 13G iDRAC devices, go to the iDRAC console, or collect by clicking Troubleshooting
> Extract SupportAssist Collection.
Issue 3
Description: Onboarding task will result in an error state for Windows server after correlation with Redfish protocol and has an impact on
power task execution. [84581]
Resolution: Discover devices using Redfish or WS-Man protocol, and do not discover using Redfish and Windows protocol together.
Firmware updates
Issue 1
Description: The Chassis firmware can be updated by using either the .cmc, .exe, or .bin individual packages. [79242]
Resolution: The firmware update for M1000e, VRTX, and FX chassis is supported by clicking Configuration > Firmware. Not by clicking
Firmware on the Device Details page or from the Firmware menu of a single device.
Resolution: Wait until the cloned task is displayed in both the Remote Tasks tree and the Remote Tasks grid, and then verify the task
targets.
Issue 2
Description: Catalog is not created on the Windows NFS share. [84823]
Resolution: If you are using a Windows NFS share, refer to the Microsoft KB article about permissions mapping at https://
technet.microsoft.com/en-us/library/cc770843(v=ws.11).aspx#BKMK_15.