Release Notes
Description: An individual Chassis Management Controller (CMC) health may not be correctly displayed in the device drill-down operation.
[85977]
Resolution: Always consider the CMC rollup health status.
Issue 21
Description: Certain SNMP alerts are undefined for the S4810 networking switch. [85016]
Resolution: N/A
Issue 22
Description: An unknown Error message occasionally displayed in the SNMP alert console. [84894]
Resolution: Ignore or click Dismiss.
Issue 23
Description: In the SNMP alert console, some alerts from OMSA correctly show the Message ID field, while others show N/A. [83579]
Resolution: N/A
Issue 24
Description: Discovery of an HP server by using IPMI command may not reflect the correct rollup health status. [85153]
Resolution: View the lower-level sensor health data.
Issue 25
Description: In the Execution Details section, data must be manually sorted in the table every time after moving to a new page. [81207]
Resolution: Sort information of a single page at a time.
Issue 26
Description: Currently, the health status including PSU and temperature data is not displayed for the storage devices. [99821]
Resolution: N/A
Issue 27
Description: : The rollback features is not supported on the MX7000 chassis. Also, the rollback operation fails on the M1000e, FX2, and
FX2s chassis. [110239]
Resolution: For M1000e, FX2, and FX2s chassis, create and associate a new baseline with the necessary firmware version to roll back.
Issue 28
Description: Currently, the alerts are not received by OpenManage Enterprise if the alerts are associated with the devices' IP address.
However, alerts are successfully received when associated with the device Service Tag. [106369]
Issue 29
Description: Invalid host names are displayed under the Source Name column and are also available for selection in some of the
OpenManage Enterprise tasks. [68214]
Issue 30
Description: Authentication by one-way and two-way trusts of AD users is not supported by the appliance.
Issue 31
Description: From the All Devices page, you cannot launch the iDRAC application interface with IPv6 addresses. [102153]
Issue 32
Description: When PCIe cards are mapped to the FX2/FX2s chassis, migration of identities is not supported on the sleds in the same
FX2s chassis since the FQDDs differ.
Issue 33
Description: Console Upgrade from 3.0 through NFS Share fails. Also, console Upgrade through HTTPS (internal Share) fails when
upgrading from versions 3.0 and 3.1. [114683]
Resolution: Use the online method for updating, or use the HTTPS method. Ensure that the security certificates are signed by a trusted
third-party certificate authority while using the HTTPS method of update.
Issue 34
Description: The selected target devices or device groups while creating an alert policy in OpenManage Enterprise-Tech Release are
cleared when the appliance is updated. [115698]
Dell EMC OpenManage Enterprise Version 3.3.1 Release Notes