Release Notes
Description: Emails for alert policies doesn't work when the same event is generated twice within 2 minutes. Email action for alerts
containing the same message ID and content are triggered every 2 minutes to avoid many repeated/redundant alert messages in the
inbox.[148407]
Issue 8
Description: While creating a customized device discovery job protocol for SNMP devices, the displayed default settings of 3 in the
Retries box and 3 seconds in the Timeout box can be overlooked and should be customized as desired. [147416]
Issue 9
Description: When updating local shares for a manual upgrade for versions without any installed extensions/plugins (such as 3.1 and 3.2),
the audit log displays warning entries such as 'Unable to retrieve the source file of type Extension Catalog because the file does not exist'
and 'The status of downloading the Extension Catalog is Failed'. These error messages do not have any functional impact on the upgrade
process and can be ignored. [144379]
Issue 10
Description: Clicking Check Update on OpenManage Enterprise version 3.2, where PowerManager extension is not installed, an error
CGEN1003- Unable to complete the operation because an empty payload is not allowed for this
request is displayed.
Resolution: This error can be ignored as it is for information purpose only. There is no functional impact of this error and the user can go
ahead with the upgrade.
Issue 11
Description: OpenManage Enterprise could be impacted by the Linux TCP SACK vulnerability (CVE-2019-11477).
Resolution: OpenManage Enterprise includes CentOS kernel patches for the TCP SACK Panic issues and carries the updated
kernel-3.10.0-957.21.3.el7.x86_64.rpm including fixes for the CVE-2019-11477 vulnerability.
Issue 12
Description: Post console update Time interval should be enabled manually in alert policy as it is disabled by default.
Issue 13
Description: Alert policies have been recategorized in OpenManage Enterprise version 3.3.1. The alert policies created before the upgrade
that are impacted because of the recategorization, would need to be recreated.
Issue 14
Description: A query group with switch and device power state together is not working as expected. [86481]
Resolution: Exclude switch power state while creating a query group.
Issue 15
Description: The management IP is incorrectly indicated if the server is discovered by using both the IPv4 and IPv6 addresses. [86196]
Resolution: Manually start the iDRAC Graphical User Interface (GUI).
Issue 16
Description: The target IP address is incorrectly listed in the task history of an alert policy that is created by running a remote script.
[86424]
Resolution: N/A
Issue 17
Description: Not all scheduled jobs are displayed in the Recent Tasks list. [86488]
Resolution: Go to the Jobs page to view the latest and complete list of jobs.
Issue 18
Description: Discovery operation fails by using IPMI commands on the CISCO server if a KG key is used. [78545]
Resolution: KG key is not supported for this device discovery.
Issue 19
Description: When a device is turned off, the console takes a few moments to display the updated health status. [86146]
Resolution: Refresh the browser, or wait for a few moments.
Issue 20
6