Release Notes
Issue 14
Description: Template Deployment with iDRAC Management IP option "Set as DHCP" fails, and the task has to be tracked from iDRAC
for final status.
Others
Issue 1
Description: A query group with switch and device power state together is not working as expected. [86481]
Resolution: Exclude switch power state while creating a query group.
Issue 2
Description: The management IP is incorrectly indicated if the server is discovered by using both the IPv4 and IPv6 addresses. [86196]
Resolution: Manually start the iDRAC Graphical User Interface (GUI).
Issue 3
Description: The target IP address is incorrectly listed in the task history of an alert policy that is created by running a remote script.
[86424]
Resolution: N/A
Issue 4
Description: Not all scheduled jobs are displayed in the Recent Tasks list. [86488]
Resolution: Go to the Jobs page to view the latest and complete list of jobs.
Issue 5
Description: Discovery operation fails by using IPMI commands on the CISCO server if a KG key is used. [78545]
Resolution: KG key is not supported for this device discovery.
Issue 6
Description: When a device is turned off, the console takes a few moments to display the updated health status. [86146]
Resolution: Refresh the browser, or wait for a few moments.
Issue 7
Description: An individual Chassis Management Controller (CMC) health may not be correctly displayed in the device drill-down operation.
[85977]
Resolution: Always consider the CMC rollup health status.
Issue 8
Description: Certain SNMP alerts are undefined for the S4810 networking switch. [85016]
Resolution: N/A
Issue 9
Description: An unknown Error message occasionally displayed in the SNMP alert console. [84894]
Resolution: Ignore or click Dismiss.
Issue 10
Description: In the SNMP alert console, some alerts from OMSA correctly show the Message ID field, while others show N/A. [83579]
Resolution: N/A
Issue 11
Description: Discovery of an HP server by using IPMI command may not reflect the correct rollup health status. [85153]
Resolution: View the lower-level sensor health data.
Issue 12
Description: In the Execution Details section, data must be manually sorted in the table every time after moving to a new page. [81207]
Resolution: Sort information of a single page at a time.
Issue 13
Dell EMC OpenManage Enterprise Version 3.2 Release Notes
5