Description: The built-in Virtual Disk report contains duplicate or empty values if the virtual disks and physical disks don't have
any associations and are used individually. This issue is not observed if the VDs an PDs are being used together. [174851]
Resolution: It is recommended to use a custom report to get only the virtual disk data if the VDs and PDs are not associated.
Issue 5
Description: Even with the MX7000 onboarding preference set as 'Receive Chassis category alerts only' in the appliance, you
might receive alerts of all categories (iDRAC, Network IOMs, Storage IOMs) from the newly-onboarded MX7000 chassis.
[180323]
Resolution: To view only the MX7000 chassis category alerts on the Alert Log page, it is recommended that you use the
Advanced Filters.
Issue 6
Description: For Ubuntu devices, the OS Version under operating system information (from iDRAC/ISM) on the Device
Overview page is not displayed. [171103]
Issue 7
Description: With the Japanese version of the appliance, it is observed that the PDF export of the Warranty page contains
illegible characters. [176493]
Resolution: For the Warranty page export use the CSV or HTML formats.
Issue 8
Description: When the appliance is configured to IPv6, it is unable to reach the targets like SMTP, syslog servers and share
through FQDNs which is resolvable to both IPv4 and IPv6. [153980]
Resolution: When the features that use FQDN fail, it is recommended to check the interface and use the corresponding IP. For
instance, if the primary network is enabled with only IPv6, and the FQDN expected to work on primary interface fails, user can
use IPv6 address in the place of FQDN as a workaround. This applies for secondary interface as well.
Issue 9
Description: Description: The Text User Interface (TUI) screen is not displayed until the 'Enter' key is pressed after updating
the appliance to version 3.4.1 on ESXi with large deployments involving 8,000 or more devices. [173206]
Issue 10
Description: Creating a report with chassis table columns and device table columns using a query with an 'or' will not generate
a report with expected result. [154713]
Issue 11
Description: When a Lead chassis retires and a backup chassis becomes the new lead on OpenManage Enterprise, the refresh
inventory marks the original backup chassis and its associated devices to be invisible and not shown in the UI. [161300]
Resolution: Discover the new Lead on OpenManage Enterprise.
Issue 12
Description: "Virtual identity by usage report" does not display the identity state as "Used" when the virtual identities were
assigned to a device from an external source. The current reports do not support the "Used" status, and instead display them as
either 'Reserved' or 'Assigned'. [160507]
Issue 13
Description: The rack physical groups with long names consisting of more than 150 characters with no spaces, the appliance
wizards experiences an 'overflow'. [164157]
Resolution: Limit the number of characters used to create names.
Issue 14
Description: If a Configuration Inventory task finds external identities that fall in an existing identity pool and that identity pool
is later deleted and a new one with the same or overlapping identities is created, the new identity pool will not show those
identities as assigned. [160888]
Issue 15
Description: OpenManage Enterprise appliance does not prevent unauthorized shell access by an end user with FSD enabled.
The GRUB bootloader allows root level shell access during boot. [162922]
Issue 16
Description: Complete inventory is not collected when a sled is removed and reinserted in the chassis. [165192]
11