White Papers
A Technical support and resources
28 Benchmark the Performance, Reliability, and Scalability of Dell EMC OpenManage Enterprise 3.4 in your data
center environment | 14465
4. Scalability and performance test results of OpenManage
Enterprise 3.4 (tested on 20 MX7000 chassis MCM setup)
4.1 Performance results for managing a 20 chassis MCM setup from
OpenManage Enterprise 3.4
• Test setup: MCM setup with 1 Lead and 1 backup Lead.
- MX7000 chassis: 20
- PowerEdge MX740c: 124
- PowerEdge MX840c: 11
- Dell EMC MX7116n Fabric Expander: 2
- Dell EMC MX9116n Fabric Engine: 1
- MX7116n Fabric Expander Module: 57
- Dell EMC MX9116n Fabric Engine: 5
- To discover the chassis, selected the Chassis option from the discovery wizard while creating the
discovery task.
- WSMAN protocol is automatically used for the sub-discovery task of sleds present in a Chassis.
- Time taken for discovery and inventory of 20 chassis MCM, includes the sub-discovery of sleds.
- To run the Status Poll, users can select all MX7000 chassis from All devices page after discovery
and click on the refresh status option.
- Time taken for rediscovery of the 20 MX7000 chassis is less than the first-time discovery.
Discovery and inventory of MX7000 chassis
Protocol used for discovery
Redfish for chassis
WSMAN for servers
Number of chassis discovered
20
Time taken for first discovery,
inventory, of 20 chassis MCM with
lead IP and onboarding of chassis
30m
Time taken for scheduled
rediscovery
24m
Time taken for Status Poll of 20
MX7000 chassis
10s