Users Guide

Related tasks
Delete alert policies on page 98
Disable alert policies on page 97
Enable alert policies on page 97
Edit alert policies on page 97
Create alert policies on page 93
Automatic refresh of MX7000 chassis on insertion and removal
sleds
OpenManage Enterprise can almost instantly reflect the addition or removal of sleds after a standalone or a lead MX7000
chassis is discovered or onboarded.
When a standalone or a lead MX7000 chassis is discovered or onboarded by using OpenManage Enterprise version 3.4, an alert
policy is created simultaneously on the the MX7000 chassis. For more information on discovering and onboarding devices in
OpenManage Enterprise, see Create a device discovery job on page 107 and Onboarding devices on page 108.
The automatically-created alert policy on the MX7000 OpenManage Enterprise-Modular appliance triggers a chassis inventory
refresh job, named Refresh Inventory of Chassis in OpenManage Enterprise every time a sled is inserted, removed, or
replaced in the MX7000 chassis.
Post completion of the chassis- inventory-refresh job, the sled-related changes to the MX7000 are displayed on the All Devices
page.
The following prerequisites must be met while onboarding the MX7000 chassis for a successful creation of the automatic alert
policy :
OpenManage Enterprise-Modular version 1.2 must be already installed in the MX7000.
MX7000 chassis should be onboarded with the options 'Enable trap reception from discovered iDRAC servers and
MX7000 chassis' and 'Set Community String for trap destination from Application Settings'.
The OpenManage Enterprise appliance IP should get successfully registered as one of the four available alert destinations in
the newly-onboarded MX7000. If all the alert destinations in the MX7000 are already configured at the time of onboarding,
then the automatic alert policy creation will fail.
NOTE:
The alert policy on MX7000 is only specific to the sleds and are not applicable to the other components of the chassis,
such as the IOMs.
MX7000 alert preferences can be set in OpenManage Enterprise to either receive all the alerts or only the chassis-
category alerts from the MX7000 chassis. For more information, see Manage Console preferences on page 141.
Some delay is to be expected between the actual action on the sleds and the triggering of the chassis inventory
refreshing on OpenManage Enterprise.
The automatically created alert policy is deleted if the MX7000 chassis is deleted from the device inventory of
OpenManage Enterprise.
The All Devices page will list the Managed State for a successfully onboarded MX7000 chassis with automatic alert
forwarding policy as 'Managed with Alerts'. For more information on onboarding, refer Onboarding devices on page 108
Create alert policies
NOTE:
To perform any tasks on OpenManage Enterprise, you must have the necessary user privileges. See Role-based
OpenManage Enterprise user privileges on page 14.
1. Click Alert Policies > Create.
2. In the Create Alert Policy dialog box, in the Name and Description section, enter the name and description of the alert
policy.
a. To enable an alert policy by default, select the Enable Policy check box.
b. Click Next.
Monitoring device alerts