Release Notes

Description: Firmware upgrade fails when iDRAC firmware versions older than 2.40.40.40 are upgraded directly to 2.63.60.61 with an
error message Unable to verify Update Package signature. This failure happens as the firmware versions older than 2.40.40.40
cannot validate the latest SHA-256 digital signature of the Dell Update Packages. [146564]
Resolution: First upgrade the older iDRAC firmware versions to 2.40.40.40 before attempting an upgrade to iDRAC firmware version
2.63.60.61.
Issue 10
Description: The Update Firmware button remains enabled even when there are no firmware catalogs available for upgrade or
downgrade. [108218]
Issue 11
Description: The firmware rollback on the PowerEdge MX7000 sleds is not supported. Also, rollback on sleds is not supported when the
onboarding state of the sleds is Proxied.[116172]
Issue 12
Description: A job for firmware rollback on the PowerEdge MX7000 sleds, though allowed in the appliance, would fail. This happens
because the firmware rollback is not supported on the MX series sleds discovered as part of MX7000 chassis discovery or in proxied state.
[136820]
Issue 13
Description: When updating MX7000 chassis in the MCM mode, always make sure that the lead chassis is updated as the final step after
updating all the member chassis. Also, chassis and sled firmware updates must be initiated separately. [168883]
Issue 14
Description: The Firmware Update task fails on the MCM member chassis with error message 'Syncing data with passive MM Task
Failed. Completed With Errors'. [169333]
Configuration management
Issue 1
Description: Same inventory details can be present on two servers post migration, as the 'true' target-specific attributes are not
reclaimed from the 'source' server as part of migration. [160622]
Issue 2
Description: The Reclaim Identities and Profile Migration features are not supported for Emulex OneConnect Cards. [98511]
Issue 3
Description: If the MX7000 chassis is in the 'monitored' state during stateless deployment, the deployment job fails because the user
does not have necessary privileges. Only the server configuration profile is imported. However, this information is not displayed in the Task
Execution section. [108484]
Issue 4
Description: The changed VLAN name and IDs are not updated on the target MX7000 chassis after a stateless deployment task is run.
[105156]
Issue 5
Description: If the IP setting is not configured on the discovered PowerEdge MX740C and PowerEdge MX840C, the Boot to Network
ISO operation is not run during the template deployment. [102887]
Issue 6
Description: After deploying an MX7000 chassis template, you cannot log in to the MX7000 chassis with LDAP credentials. [107230]
Resolution: Manually update the LDAP Bind password to log in.
Issue 7
Description: If a chassis template is deployed with a new static IP address on the FX2, VRTX, and M1000e chassis, then these devices
need to be re-discovered with the new IP for managing the device.
Issue 8
Description: The deployment task of an MX7000 chassis fails if proxy authentication is enabled in the configuration template with error:
'Unable to complete the request because the input value for Password is missing or an invalid value is entered'. [108779]
Issue 9
Description: The directory service details in an MX7000 chassis are overwritten after the device configuration template is deployed.