Release Notes
Table Of Contents
Description: When a 'scoped' device manager uses Global Search, the total search count exceeds the actual items displayed.
[197629]
Issue 5: Run Inventory on Group is unavailable for Device Manager users.
Description: For the Device Manager users, Run Inventory on Group option under Inventory on the All Devices page is
unavailable. [193441]
Discovery and inventory
Issue 1: Chassis Health State shows as disconnected for 10 minutes after the chassis administrator password is reset.
Description: When the Administrator password is reset on any discovered chassis (MX7000, M1000e, VRTX,and FX2), there is
a disconnection of the chassis with the appliance for 600 seconds. During this interval, the Health State of the chassis on the All
Devices page is displayed as 'Disconnected' and the tasks initiated on the chassis and sleds fail. [198434]
Issue 2: Post deletion of 8K devices, Onboarding task does not trigger during next discovery cycle.
Description: Post deletion of 8,000 devices from the appliance, the automatic onboarding task fails during the next discovery
cycle. [200458]
Resolution: Restart the services from the Text User Interface (TUI) page.
Issue 3: Mismatch seen in CIQ data and OME device inventory for RaidControllerId.
Description: The RaidControllerId attribute in the ServerRaidControllers component in OpenManage Enterprise inventory and
CIQ device data inventory have different values for the same device. [185745]
Issue 4: Duplicate entries displayed for third party devices when discovered using multiple protocols.
Description: For third party devices such as the HPE Proliant servers, you might see duplicate entries if they are discovered
using multiple protocols. This duplication can be corrected by deleting the entries and rediscovering the device(s) using only the
IPMI protocol. [180572]
Issue 5: Unable to retrieve hardware logs for HPE servers.
Description: For the discovered HP servers, the devices' Hardware Logs are not displayed as the third party library used by the
appliance is unable to extract the hardware logs for HP iLO servers. [170550]
Issue 6: HPE servers display incorrect power supply data.
Description: For the discovered HP servers, the 'Power Supply' details are not displayed under the subsystem health section
on the device's Overview page. This detail is missing as the third party API that is used to gather sensor health details, doesn't
provide the 'Power Supply' data. [85153]
Issue 7: HPE servers do not display certain FRU fields.
Description: For the discovered HP servers, the following field-replaceable unit (FRU) details are not displayed under the
device's Hardware page: Memory FRU details, BIOS - Part number and version, BMC controller - Part number. [75653]
Issue 8 : DIMM information is not available on Hypervisors.
Description: For the discovered Hyper-V servers, the Populated DIMM Slots and the Total DIMM Slots fields are displayed as
'0' on the device's Overview page. [IT-84431]
Issue 9: MAC address not displayed for the discovered Windows servers.
Description:For the discovered Windows servers using Open SSH, the MAC address is not displayed on the device's Hardware
> Device Management Info page. [181229]
Issue 10 : Few invalid IP range formats are not being validated when creating a Discovery job.
Description: While discovering devices, a few invalid IP and IP-range formats are not being rejected by the Create Discovery
Job wizard, resulting in 'failed' Discovery jobs. [178692]
Resolution: Invalid IP or IP-range formats, as mentioned in the Context Help(i), must not be used for device discovery.
Issue 11: Unclear error message on failure of Windows server discovery using SSH.
Description: Discovery of Windows server(s) using non-admin credentials fails with an error message 'Unable to connect to the
device over SSH because a connection error occurred.' This must be interpreted instead as 'Unable to perform the requested
action because the device management endpoint authentication over SSH failed'. [158088]
Issue 12: Guest Information for Hyper-V 2012 R2 is not available.
Description: The Guest information for the discovered Hyper-V 2012 R2 servers is not available on the device's Hardware page.
[159535]
6