Description: Console Upgrade from 3.0 through NFS Share fails. Also, console Upgrade through HTTPS (internal Share) fails
when upgrading from versions 3.0 and 3.1. [114683]
Resolution: Use the online method for updating, or use the HTTPS method. Ensure that the security certificates are signed by
a trusted third-party certificate authority while using the HTTPS method of update.
Issue 55
Description: While programmatically deploying the OpenManage Enterprise from Linux shell, if the argument provided for
--name= in the command line begins with a "$" then the argument is ignored and appliance is deployed with the name
OPENMANAGE ENTERPRISE. [121158]
Resolution: The --name= argument, which begins with "$" in the command line must be enclosed in single quotes, for example,
--name= '$OME-VM'.
Issue 56
Description: The Severity status in the Alert log for the alerts received from the PowerVault ME4 storage arrays is being
reported as Unknown by the appliance. This defect is due to the unavailability of the precanned MIBs for the PowerVault ME4
storage arrays in the appliance console. [122657]
Issue 57
Description: After the console is upgraded, there is a delay of approximately 15 minutes in the initiation of the Post Upgrade
task by the appliance. [130142]
Issue 58
Description: When an already imported MIB is renamed and parsed through API the trap status is reported as 'Existing' instead
of 'Imported.'[111854]
Issue 59
Description: Ignore alert policy created for warranty, firmware compliance, and configuration compliance alerts will be ignored
only if alerts are generated from the same device from which ignore policy was created. In other cases, alerts will be received
and not ignored. [124596]
Issue 60
Description: SSH Private key can be applied while adding a remote script in the Script Execution page. [129366]
Issue 61
Description: The Schedule advanced filter in the Monitor > Discovery page incorrectly displays even those discovery jobs
which have completed their initial scheduled run. [128842]
Issue 62
Description: All the AD/LDAP groups imported from the OpenManage Enterprise versions before version 3.2, such as the
version 3.1 and version 3.0, should be deleted and re-imported.
Issue 63
Description: The .CSV files, that record the deleted alerts from the Alert log, fail to capture the Device Name and the Device
IP details of the alerts received from the undiscovered devices.[132915]
Issue 64
Description: Export of large firmware compliance reports, containing more than 200,000 elements, fails and the appliance
displays an Application timeout error. [133201]
Resolution: When exporting large firmware compliance reports, the following workarounds can be employed :
● Allocate more memory to the appliance while installing.
● Before exporting large reports, ensure that other jobs are not running.
● Use the Firmware Compliance per Component or the Firmware Compliance per Device Report instead of exporting.
● Use filters to derive a smaller result set before exporting.
Issue 65
Description: A "Connection to server failed" error is displayed by the failed Power Action Tasks. Power Action tasks fail when
they encounter servers where no power state change is required. This error message, though misleading, does not mean that
the appliance is unable to establish contact with the server. [136816]
Issue 66
Description: The Monitor > Jobs > View Detail Execution History page incorrectly displays Could not set alert
destination on the target under Messages, even for the successfully-completed jobs created for setting of trap destinations
for the MX7000 chassis.