Release Notes
Table Of Contents
Description: Attempt to redeploy a profile to a new target, after the profile is unassigned from its earlier target, fails with
a 'CGEN6008 -Unable to process the request......' error. This error is exhibited even when the previous and new target are
identical to each other. [204655]
Issue 6
Description: Deployment of a second template on a chassis is allowed even when a profile is already deployed on it. [204441]
Issue 7
Description: If only VLANs are assigned to a target device during profile deployment, then these VLANs are not reclaimed by
the appliance when the profile is unassigned from the device. This behavior is not seen if other identities were assigned along
with VLAN definitions during the profile deployment. [174360]
Issue 8
Description: User Password attributes can't be set on the MX7000 and the Chassis Management Controller Deployment
templates. [200293]
Issue 9
Description: If only VLANs are assigned to a target device during profile deployment, then these VLANs are not reclaimed from
the device when the profile is migrated to a new device. This behavior is not seen if other identities were assigned along with
VLAN definitions during the profile deployment. [174576]
Issue 10
Description: Profile redeployment on FX2, VRTX, and M1000e chassis with edited VLAN configuration (tagged and untagged
values), clears only those VLAN values which were set during the initial deployment of the profile. The other VLAN values on the
ports that were not set during the initial deployment of the profile are not cleared during redeployment. [175692]
Issue 11
Description: Same inventory details can be present on two servers post migration, as the 'true' target-specific attributes are
not reclaimed from the 'source' server as part of migration. [160622]
Issue 12
Description: The Reclaim Identities and Profile Migration features are not supported for Emulex OneConnect Cards. [98511]
Issue 13
Description: If the MX7000 chassis is in the 'monitored' state during stateless deployment, the deployment job fails because
the user does not have necessary privileges. Only the server configuration profile is imported. However, this information is not
displayed in the Task Execution section. [108484]
Issue 14
Description: The changed VLAN name and IDs are not updated on the target MX7000 chassis after a stateless deployment
task is run. [105156]
Issue 15
Description: If the IP setting is not configured on the discovered PowerEdge MX740C and PowerEdge MX840C, the Boot to
Network ISO operation is not run during the template deployment. [102887]
Issue 16
Description: After deploying an MX7000 chassis template, you cannot log in to the MX7000 chassis with LDAP credentials.
[107230]
Resolution: Manually update the LDAP Bind password to log in.
Issue 17
Description: If a chassis template is deployed with a new static IP address on the FX2, VRTX, and M1000e chassis, then these
devices need to be re-discovered with the new IP for managing the device.
Issue 18
Description: The deployment task of an MX7000 chassis fails if proxy authentication is enabled in the configuration template
with error: 'Unable to complete the request because the input value for Password is missing or an invalid value is entered'.
[108779]
Issue 19
Description: The directory service details in an MX7000 chassis are overwritten after the device configuration template is
deployed.
Issue 20