Release Notes
Table Of Contents
Resolution: After updating the appliance, edit the alert policy and select the target devices or device groups to receive the
group-specific alerts.
Issue 74
Description: After you update the appliance from OpenManage Enterprise-Tech Release, the Syslog server messages
do not retain the standard format of <timestamp><hostname>_<Alert_Message>. The alerts are displayed as
"EEMI@123_[id]":Alert_Message. [115699]
Issue 75
Description: Few alerts from the PowerEdge R240, R340, T140, T340, and R740xd2 servers are received with unknown
severity in the OpenManage Enterprise appliance. [112404]
Issue 76
Description: While programmatically deploying the OpenManage Enterprise from Linux shell, if the argument provided for
--name= in the command line begins with a "$" then the argument is ignored and appliance is deployed with the name
OPENMANAGE ENTERPRISE. [121158]
Resolution: The --name= argument, which begins with "$" in the command line must be enclosed in single quotes, for example,
--name= '$OME-VM'.
Issue 77
Description: The Severity status in the Alert log for the alerts received from the PowerVault ME4 storage arrays is being
reported as Unknown by the appliance. This defect is due to the unavailability of the precanned MIBs for the PowerVault ME4
storage arrays in the appliance console. [122657]
Issue 78
Description: After the console is upgraded, there is a delay of approximately 15 minutes in the initiation of the Post Upgrade
task by the appliance. [130142]
Issue 79
Description: When an already imported MIB is renamed and parsed through API the trap status is reported as 'Existing' instead
of 'Imported.'[111854]
Issue 80
Description: Ignore alert policy created for warranty, firmware compliance, and configuration compliance alerts will be ignored
only if alerts are generated from the same device from which ignore policy was created. In other cases, alerts will be received
and not ignored. [124596]
Issue 81
Description: SSH Private key can be applied while adding a remote script in the Script Execution page. [129366]
Issue 82
Description: The Schedule advanced filter in the Monitor > Discovery page incorrectly displays even those discovery jobs
which have completed their initial scheduled run. [128842]
Issue 83
Description: All the AD/LDAP groups imported from the OpenManage Enterprise versions before version 3.2, such as the
version 3.1 and version 3.0, should be deleted and re-imported.
Issue 84
Description: The .CSV files, that record the deleted alerts from the Alert log, fail to capture the Device Name and the Device
IP details of the alerts received from the undiscovered devices.[132915]
Issue 85
Description: Export of large firmware compliance reports, containing more than 200,000 elements, fails and the appliance
displays an Application timeout error. [133201]
Resolution: When exporting large firmware compliance reports, the following workarounds can be employed :
● Allocate more memory to the appliance while installing.
● Before exporting large reports, ensure that other jobs are not running.
● Use the Firmware Compliance per Component or the Firmware Compliance per Device Report instead of exporting.
● Use filters to derive a smaller result set before exporting.
Issue 86