Issue 47
Description: While creating a customized device discovery job protocol for SNMP devices, the displayed default settings of 3 in
the Retries box and 3 seconds in the Timeout box can be overlooked and should be customized as desired. [147416]
Issue 48
Description: When updating local shares for a manual upgrade for versions without any installed plugins (such as 3.1 and 3.2),
the audit log displays warning entries such as 'Unable to retrieve the source file of type Plugin Catalog because the file does not
exist' and 'The status of downloading the Plugin Catalog is Failed'. These error messages do not have any functional impact on
the upgrade process and can be ignored. [144379]
Issue 49
Description: Clicking Check Update on OpenManage Enterprise version 3.2, where PowerManager plugin is not installed, an
error CGEN1003- Unable to complete the operation because an empty payload is not allowed for
this request is displayed.
Resolution: This error can be ignored as it is for information purpose only. There is no functional impact of this error and the
user can go ahead with the upgrade.
Issue 50
Description: OpenManage Enterprise could be impacted by the Linux TCP SACK vulnerability (CVE-2019-11477).
Resolution: OpenManage Enterprise includes CentOS kernel patches for the TCP SACK Panic issues and carries the updated
kernel-3.10.0-957.21.3.el7.x86_64.rpm including fixes for the CVE-2019-11477 vulnerability.
Issue 51
Description: Post console update Time interval should be enabled manually in alert policy as it is disabled by default.
Issue 52
Description: Alert policies have been recategorized since OpenManage Enterprise version 3.3.1. The alert policies from
appliance versions before 3.3.1 need to be recreated after the appliance upgrade.
Issue 53
Description: A query group with switch and device power state together is not working as expected. [86481]
Resolution: Exclude switch power state while creating a query group.
Issue 54
Description: The management IP is incorrectly indicated if the server is discovered by using both the IPv4 and IPv6 addresses.
[86196]
Resolution: Manually start the iDRAC Graphical User Interface (GUI).
Issue 55
Description: The target IP address is incorrectly listed in the task history of an alert policy that is created by running a remote
script. [86424]
Resolution: N/A
Issue 56
Description: Not all scheduled jobs are displayed in the Recent Tasks list. [86488]
Resolution: Go to the Jobs page to view the latest and complete list of jobs.
Issue 57
Description: Discovery operation fails by using IPMI commands on the CISCO server if a KG key is used. [78545]
Resolution: KG key is not supported for this device discovery.
Issue 58
Description: When a device is turned off, the console takes a few moments to display the updated health status. [86146]
Resolution: Refresh the browser, or wait for a few moments.
Issue 59
Description: An individual Chassis Management Controller (CMC) health may not be correctly displayed in the device drill-down
operation. [85977]
Resolution: Always consider the CMC rollup health status.