Users Guide

Table Of Contents
Table 7. Text User Interface options (continued)
Options Descriptions
Enable Field Service Debug (FSD) Mode Select Enable Field Service Debug (FSD) Mode for console
debugging. For more information, see Field service debug
workflow on page 174.
Restart Services Select Restart Services with the following options to restart
the services and networking:
Restart All Services
Restart Networking
Setup Debug Logging Select Setup Debug Logging using the following options :
Enable All Debug Logs
to collect the Debug logs of the all the application
monitoring tasks, events, the task execution history,
and installed plugins.
Disable All Debug Logs
to disable all the Debug logs.
Configure Debug Logging
To selectively enable debug logging for appliance and
plugin services.
Use the Options menu to select all services, clear
all selections or restore state prior to making any
modifications.
Enable SCP Retentionto collect the template .XML
files.
Disable SCP Retentionto disable the SCP retention.
You can download the debug logs by clicking Monitor > Audit
Logs > Export > Export Console Logs in OpenManage
Enterprise.
Change keyboard layout Select Change keyboard layout to change the keyboard
layout if needed.
Reboot the Appliance Select Reboot the Appliance to restart the appliance.
NOTE: After running a command to restart the services,
the TUI may display the following message: NMI
watchdog: BUG: soft lockup - CPU#0 stuck
for 36s! [java:14439].
The soft lockup issue likely occurs as a result of the
hypervisor being overloaded. In such situations, it is
recommended to have at least 16 GB of RAM and CPU
of 8000 MHz reserved to the OpenManage Enterprise
appliance. It is also recommended that the OpenManage
Enterprise appliance be restarted when this message is
displayed.
Configure OpenManage Enterprise
If you are logging in to OpenManage Enterprise for the first time, the Welcome to OpenManage Enterprise page is displayed,
which allows setting of time (either manually or using NTP time synchronization) and proxy configurations.
1. To configure the time manually do the following in the Time Configuration section:
Use the Timezone drop down menu to select an appropriate Timezone.
In the Date box, enter or select a date.
In the Time box, fill the time.
Click Apply to save the settings.
2. If you want to use the NTP Server for time synchronization, do the following in the Time Configuration section:
Get started with OpenManage Enterprise
29