Why are few devices and groups (static or physical) are not selectable in Create Policy wizard?
Description:
If the devices or groups are not compatible with Power Manager, then you cannot select them in the Create
Policy wizard.
Device linux-yb6e is greyed out in Create Policy wizard
Resolution:
Ensure that the following prerequisites are met before applying a Static or Temperature-Triggered policy for a
monitored device or group:
The devices with valid OpenManage Enterprise license with no (or expired) iDRAC Enterprise or
iDRAC Data Center License or CMC Enterprise are greyed out on the selection page.
Empty groups or groups with no Power Manager capable devices are greyed out on the selection
page.
While creating a Temperature-Triggered policy, the groups with already existing Temperature-
Triggered policies are not available for selection.
Are there any notifications available when a membership change has occurred on a group with active
power policy or when the configured power cap gets violated?
Description:
A warning alert related to Power Configuration with ID CPWR0012 is generated to indicate that the group
membership of monitored group is updated.
Meanwhile, a critical alert with Event ID CPWR0013 is generated to indicate that the configured power policy
for a monitored group is violated.