Create Static Power Policy
13 Static Power and Temperature-Triggered Policies with OpenManage Enterprise Power Manager
Power Settings section when a device is selected
Due to few device limitations, Power Manager maintains static Upper bound and Lower bound values. For
the following list of PowerEdge servers, the range of Lower Bound to Upper Bound threshold is always a
static range:
Devices with static range of Lower Bound and Upper Bound values
Server Generation Server Model Power Cap Value Range (Watts)
14G
VxRail G560
0 - 32767
VxRail G560F
PowerEdge C6420
PowerEdge R6415
PowerEdge R7415
PowerEdge R7425
13G
PowerEdge C6320
0 - 700
PowerEdge C6320p
9. Click Next and navigate to Policy Schedule section.
a. Schedule a static power policy for a later time or enable the policy for always on the selected
device or group.
b. In Time Span, select Always for the policy to be active from the time of creation. If the policy
does not have to be active always when enabled, click Range and provide a time range during
which the policy must be active when it is enabled.
c. In Day(s), select Always for the policy to be active every day after it is enabled. If the policy does
not have to be active always, click Daily to select specific days on which the policy is active when
enabled.
d. In Active Date, select the date range when the policy is active when enabled. Select Always for
perpetual schedule.