Users Guide
Table Of Contents
- Dell EMC OpenManage Enterprise Power Manager Version 1.2 User’s Guide
- Contents
- Introduction to Power Manager
- What is new in this release
- Compatibility matrix
- License requirements
- Scalability and performance
- Getting started with Power Manager
- Monitoring and managing Power Manager metrics
- Rack management
- Manage data center during power reduction
- Quick access to Power Manager data
- Adding or removing groups from OpenManage Enterprise dashboard to monitor Power Manager data
- View power and thermal history of Power Manager groups
- Viewing top five energy consumers
- Viewing ratio of devices discovered in OpenManage Enterprise to devices added in Power Manager
- View top ten power offenders
- View top ten temperature offenders
- View top 10 underutilized racks for power and space
- View power and space headroom
- Maintaining Power Manager
- Alerts
- Reports in Power Manager
- Updating Power Manager
- Frequently Asked Questions
- Troubleshooting
- Other information you may need
NOTE: You can view only the power, temperature, and system airflow history for PowerEdge AMD processor servers.
Based on your selection, details of the granular information available are as follows:
Table 9. Granularity of data
Duration Granularity of data
6 Hours or 12 Hours or 1 Day Data is displayed based on the Metric gathering interval
set in the Preferences section.
7 Days or 1 Month Data is displayed at an interval of one hour.
3 Months or 6 Months or 1 Year Data is displayed at an interval of one day.
4. To view the latest metrics, click the refresh icon.
Table 10. List of Power Manager metrics and supported devices
Metric Supported devices
Power History (Watt)
● 12
th
and later generations of PowerEdge servers
NOTE: Cabled PSU servers are not supported.
NOTE: PowerEdge Fm120 aqua is not supported.
● PowerEdge MX7000
● PowerEdge M1000e
● PowerEdge VRTX
● PowerEdge FX2
● PowerEdge FX2s
Energy Consumption
● 12
th
and later generations of PowerEdge servers
● PowerEdge MX7000
● PowerEdge M1000e
● PowerEdge VRTX
● PowerEdge FX2
● PowerEdge FX2s
Thermal History (Celsius)
● 12
th
and later generations of PowerEdge servers
● PowerEdge MX7000
● PowerEdge M1000e
● PowerEdge VRTX
● PowerEdge FX2
● PowerEdge FX2s
CPU Utilization (%)
● 13
th
and later generations of PowerEdge Intel servers
● 15
th
and later generations of PowerEdge AMD servers
with iDRAC version 4.30.30.30 and later
I/O Utilization (%)
● 13
th
and later generations of PowerEdge servers (Intel)
Memory Bandwidth Utilization (%)
● 13
th
and later generations of PowerEdge servers (Intel)
System Airflow History (CFM)
● Nonmodular PowerEdge servers
○ Latest generation of AMD servers with iDRAC Data
Center license and iDRAC version 4.10.10.10 and
above
NOTE: 14
th
generation AMD servers with iDRAC
version 4.10.10.10 and above.
22 Monitoring and managing Power Manager metrics