Why do I not see all metric types for different types of
devices?
Cause: Different devices support different types of metrics.
Table 15. List of supported devices and metrics
Device Type Supported Metrics
12
th
generation of PowerEdge servers
Maximum, minimum, and average power
Maximum and average temperature
System airflow
Energy consumption
13
th
generation and 14
th
generation of PowerEdge servers
Maximum, minimum, and average power
Maximum and average temperature
Maximum, minimum, and average CPU utilization
Maximum, minimum, and average Input Output utilization
Maximum, minimum, and average Memory Utilization
System airflow
Energy consumption
PowerEdge M1000e, VRTX, FX2, and FX2s chassis
Maximum, minimum, and average power
Instant temperature
Energy consumption
PowerEdge MX7000 chassis
Maximum, and minimum power
Maximum and minimum temperature
Energy consumption
NOTE: Modular servers do not support System Airflow values.
Also, if all the criteria is met and still you are not able to view Power Manager data, ensure that the Server Power Monitoring
feature is enabled on the device you are discovering. To view the discovery log of a device:
1. In OpenManage Enterprise, click Monitor > Jobs.
The Jobs page is displayed.
2. Search for the discovery type job for the device and select the job.
3. Click the View Details on the right side of the tab.
Details about the job are displayed.
In the Messages: section, check the status for Server Power Monitoring feature.
NOTE: If the Server Power Monitoring feature is disabled, then the device is not compatible with Power Manager.
Why do I see a failure of EPR in audit log but EPR is applied
successfully for the device?
Cause: Applying EPR on the target device may fail due to the following reasons:
Connectivity issues between the appliance and the target device
If the target device is part of Power Manager with an expired license.
50
Frequently Asked Questions