Users Guide
Table Of Contents
- Dell EMC OpenManage Enterprise Power Manager Version 1.1 User’s Guide
- Contents
- Introduction to Power Manager
- What's new in this release
- Compatibility matrix
- License requirements
- Scalability and performance
- Power Manager workflow
- Getting started with Power Manager
- Maintaining Power Manager
- Viewing Metrics and Monitoring History in Power Manager
- Manage data center during power reduction
- Policies
- Thresholds
- Alerts
- Widgets for Power Manager
- Adding or removing groups from OpenManage Enterprise dashboard to monitor Power Manager data
- Viewing top five energy consumers
- Viewing power and thermal history of Power Manager groups
- Viewing ratio of devices discovered in OpenManage Enterprise to devices added in Power Manager
- Viewing ratio of devices discovered in OpenManage Enterprise to devices added in Power Manager
- Viewing top ten power offenders
- Viewing top ten temperature offenders
- Reports in Power Manager
- Frequently Asked Questions
- Troubleshooting
- Other information you may need
● To instantly view the latest list of devices and groups that are part of Power Manager as a result of any license
changes made on the target devices, click Run Inventory in OpenManage Enterprise, and then click the Refresh Power
Manager capabilities option on the Power Manager Settings page.
● View the count of overall power-capable devices from the Power Manager Devices Statistics section of the
OpenManage Enterprise dashboard.
Adding devices to Power Manager
To collect and monitor power and thermal utilization, and airflow data of devices, add the devices in Power Manager.
Prerequisites
Ensure that the following prerequisites are met:
● The devices have the required management console license. For more information, see the License requirements section.
● Servers have an OpenManage Enterprise Advanced license. For information about adding the license, see OpenManage
Enterprise User's Guide.
● Devices are discovered in OpenManage Enterprise. For information about discovering devices, see OpenManage Enterprise
User's Guide.
● The modular server is not in a Proxied state in OpenManage Enterprise.
About this task
To view the list of devices that are compatible with Power Manager, before running the inventory in OpenManage Enterprise
and immediately after the installation, perform the following steps:
1. In OpenManage Enterprise, click Devices > Run Inventory option.
2. If you are using OpenManage Enterprise version 3.4 or earlier, click Power Management > Monitored Devices and
Groups > Refresh the list for Power Manager capabilities tab.
If you are using OpenManage Enterprise version 3.5, click Plugins > Power Management > Monitored Devices and
Groups > Refresh the list for Power Manager capabilities tab.
The list of devices compatible with Power Manager are displayed when you start to add the devices from OpenManage
Enterprise.
To add devices, perform the following steps:
Steps
1. Launch OpenManage Enterprise.
2. If you are using OpenManage Enterprise version 3.4 or earlier, click Power Management > Monitored Devices and
Groups.
If you are using OpenManage Enterprise version 3.5, click Plugins > Power Management > Monitored Devices and
Groups.
The Monitored Devices and Groups tab is displayed.
3. Click Individual Devices > Add device(s).
The Add Devices to Power Manager page is displayed.
4. View all the devices that are discovered in OpenManage Enterprise by expanding the SYSTEM GROUPS section on the left
side and in All Devices tab, select the devices that you want to add.
5. (Optional) To filter and view the data:
a. Click Advanced Filters.
The following filters are displayed:
● Health State
● Power State
● Connection State
● Name
● Service Tag
● Model
● Type
● Managed State
16