Issue 2
Description:
After rebooting OpenManage Enterprise appliance, if you try to perform any plugin lifecycle-related actions for Power Manager,
the job is initiated in the back-end but you still see the Console and Plugins page. And, the following message is displayed after
some time: This page isn't working
Resolution:
Wait for some time, and view the status. The plugin lifecycle-related action is completed successfully.
Issue 3
Description:
For an MX7000 chassis, the power cap value is displayed as same as the upper bound value. When you manually change the
power cap percentage, the value is not updated and even if you change the value, the percentage is not updated.
Resolution:
Provide the power cap value, and save the policy. The policy imposes the specified power cap value on the selected devices or
groups.
Issue 4
Description:
Events are not generated for the following combination of temperature threshold violations:
● Lower Warning to Upper Warning
● Lower Critical to Upper Critical
● Upper Warning to Lower Warning
● Upper Critical to Lower Critical
Resolution:
Provide realistic warning and critical values so that there are no immediate alert generating temperature changes.
Issue 5
Description:
When you try to remove a device that is part of multiple groups using the REST API, then an error message is displayed.
Resolution:
To remove a device that is part of multiple groups, remove the device from the group in OpenManage Enterprise. The changes
are automatically reflected in Power Manager.
Issue 6
Description:
When devices are simultaneously added to and removed from a static group through OpenManage Enterprise, there are multiple
entries of this update in the Audit Logs and Alert Log.
Issue 7
Description:
When you change the power and temperature units in Power Manager through REST APIs and check for the unit change
updates in UI, the updates are not reflected on the UI.
Resolution:
To view the updates on the UI after changing the power and temperature units through REST APIs, refresh the browser.
Issue 8
Description:
When you rediscover a device or an inventory job is in progress in OpenManage Enterprise, the following error message is
displayed: Value entered for id is invalid
Resolution: