Users Guide

Table 9. List of supported devices and metrics
Device Type Supported Metrics
12
th
generation of PowerEdge servers
Maximum, minimum, and average power
Maximum and average temperature
System airflow
Energy consumption
13
th
generation and 14
th
generation of PowerEdge servers
Maximum, minimum, and average power
Maximum and average temperature
Maximum, minimum, and average CPU utilization
Maximum, minimum, and average Input Output utilization
Maximum, minimum, and average Memory Utilization
System airflow
Energy consumption
PowerEdge M1000e, VRTX, FX2, and FX2s chassis
Maximum, minimum, and average power
Instant temperature
Energy consumption
PowerEdge MX7000 chassis
Maximum, and minimum power
Maximum and minimum temperature
Energy consumption
NOTE: Modular servers do not support System Airflow values.
Why do I see a failure of EPR in audit log but EPR
is applied successfully for the device?
Cause: Applying EPR on the target device may fail due to the following reasons:
Connectivity issues between the appliance and the target device
If the target device is part of Power Manager with an expired license.
Why do I see a failure of EPR in audit log but EPR
is applied successfully for the group?
Cause: When EPR option is applied for a group, and if the EPR option is applied successfully for at least one device in the group, we can
see the EPR banner at the group level. However, the EPR option may fail on other devices of the group due to connectivity issues or
license expiry and so on. Hence, there are EPR audit logs for successful and failure scenarios for all devices of the group.
Why are devices not listed for addition to Power
Manager?
Cause: You cannot view certain devices in Power Manager because of the following reasons:
If devices do not have OpenManage Enterprise Advanced license
If the devices are discovered in OpenManage Enterprise, and then Power Manager is installed, then the devices are not displayed in
Power Manager until you Run Inventory on OpenManage Enterprise.
Devices like switches, storage sleds, Input/Output Modules are not supported in Power Manager.
Servers that are discovered through the Operating System(In-Band) are not supported in Power Manager.
Frequently Asked Questions
35