White Papers

Frequently Asked Questions
36 Emergency Power Reduction (EPR) feature with OpenManage Enterprise Power Manager
Can I apply EPR (Throttle) on an MX7000 chassis which is configured as a member in MCM mode?
Description:
EPR Throttle option is not available from Devices > Power Management and Monitoring > Policies and EPR
tab and hence cannot be enabled directly on a MX7000 chassis which is added as a member in MCM group.
Meanwhile, EPR throttle can be enabled on a Lead MX7000 chassis and the same power configuration is
replicated on the member MX7000 chassis based on the propogation rules configured for Power attribute in
MSM console.
Note: EPR (Throttle) applied on Lead MX7000 chassis is not replicated on the member MX7000 chassis if
Power attribute is not selected in the propogation rules configured for MCM group.
Select configurations in MSM which needs to be deployed to all group members
Note: Audit log entries in OpenManage Enterprise is available only for the EPR feature enabled on Lead
MX7000 chassis since the propogation of power configuration is managed by MSM.