Users Guide

3. To add the Unmonitored Devices, click Add.
The Add Unmonitored Devices page is displayed.
4. Provide the device details and click Finish.
For information about each field, see the following table.
Table 15. Details for Unmonitored Devices
Field Description Mandatory Value Ranges
Device Name Provide a unique device
name.
Yes Combination of characters,
special characters, and
numbers.
Limit: 1-255 characters
Description Provide brief information
about the device you are
adding.
No Combination of characters,
special characters, and
numbers.
Limit: 0-255 characters
Hostname Provide a hostname. No Combination of characters,
special characters, and
numbers.
Limit: 1-255 characters
Identifier Provide a unique identifier
for the device.
Yes Combination of characters,
special characters, and
numbers.
Limit: 1-255 characters
Model Provide the model name. No Combination of characters,
special characters, and
numbers.
Limit: 0-255 characters
Size of Device (U) Provide the space occupied
on the rack.
Yes Numbers only
Limit: 1-80
Estimated Max Power (W) Provide the defined
maximum power that the
device can consume.
No Numbers only
Limit: 1629365631
Physical groups
Power Manager enables you to replicate and update the physical organization and hierarchy of a data center. Using the
following hierarchyData Center, Room, Aisle, and Rack create the physical groups and add the devices at the rack level.
The physical groups that are create or deleted in OpenManage Enterprise are automatically added or removed from Power
Manager.
Creating physical groups
About this task
To replicate a data center hierarchy, perform the following steps:
32
Rack management