Users Guide
Dell EMC Enterprise switch events are not received at
the Netcool/OMNIbus console
For S-Series, M-Series, Z-Series, and C-Series Switches
1 Verify that the following entries are included in the SNMP probe rules le:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.lookup"
2 Verify that the following entries are included in the dell.master.include.lookup le:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.switch.master.include.snmptrap.lookup"
3 Verify that the following entries are included in the dell.master.include.rules le:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.switch.master.include.snmptrap.rules"
Dell EMC N-Series switch events are not received at
the Netcool/OMNIbus console
1 Verify that the following entries are included in the SNMP probe rules le:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.lookup"
2 Verify that the following entries are included in the dell.master.include.lookup le:
• include "$NC_RULES_HOME/include-snmptrap/dell/
dell.Nseriesswitch.master.include.snmptrap.lookup"
3 Verify that the following entries are included in the dell.master.include.rules le:
• include "$NC_RULES_HOME/include-snmptrap/dell/
dell.Nseriesswitch.master.include.snmptrap.rules"
Dell EMC W-Series switch events are not received at
the Netcool/OMNIbus console
1 Verify that the following entries are included in the SNMP probe rules le:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.lookup"
2 Verify that the following entries are included in the dell.master.include.lookup le:
• include "$NC_RULES_HOME/include-snmptrap/dell/
dell.Wseriesswitch.master.include.snmptrap.lookup"
3 Verify that the following entries are included in the dell.master.include.rules le:
• include "$NC_RULES_HOME/include-snmptrap/dell/
dell.Wseriesswitch.master.include.snmptrap.rules"
Dell EMC OpenManage Server Administrator events
are not correlated
Verify that the following triggers are enabled in Netcool/OMNIbus ObjectServer:
• dell_omsa_clear
• dell_omsa_deduplicate_clear
42