3 Verify that the iDRAC7/iDRAC8/iDRAC9 device has a valid SYSTEM FQDN (server host name) and is resolvable in both the Desktop
and the WEB GUI servers.
4 Verify that the server OMSA console is congured with the default port number 1311.
PowerEdge server, PowerVault NX Storage Arrays,
and Workstation events are not received at the
Netcool/OMNIbus console
1 Verify that the following entries are included in the SNMP probe rules le:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.lookup"
2 Verify that the following entries are included in the dell.master.include.lookup le:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell-MIB-Dell-
10892.include.snmptrap.lookup"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell-StorageManagement-
MIB.include.snmptrap.lookup"
3 Verify that the following entries are included in the dell.master.include.rules le:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell-MIB-Dell- 10892.include.snmptrap.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell-StorageManagement-
MIB.include.snmptrap.rules"
iDRAC7, iDRAC8 and iDRAC9 Server events are not
received at the Netcool/OMNIbus console
1 Verify that the following entries are included in the SNMP probe rules le:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.lookup"
2 Verify that the following entry is included in the dell.master.include.lookup le:
include "$NC_RULES_HOME/include-snmptrap/dell/dell-IDRAC-MIB.include.snmptrap.lookup"
3 Verify that the following entry is included in the dell.master.include.rules le:
include "$NC_RULES_HOME/include-snmptrap/dell/dell-IDRAC-MIB.include.snmptrap.rules"
Dell EMC FX2 CMC, Dell EMC VRTX CMC, Dell EMC
CMC and Dell EMC DRAC events are not received at
the Netcool/OMNIbus console
1 Verify that the following entries are included in the SNMP probe rules le:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.lookup"
2 Verify that the following entry is included in the dell.master.include.lookup le:
include "$NC_RULES_HOME/include-snmptrap/dell/dell-RAC-MIB.include.snmptrap.lookup"
3 Verify that the following entry is included in the dell.master.include.rules le:
include "$NC_RULES_HOME/include-snmptrap/dell/dell-RAC-MIB.include.snmptrap.rules"