Users Guide
Alert Group Description
FanSpeedThreshold Provides information that fan speed has exceeded the minimum or maximum threshold.
FanTrayRemoved Provides information that one of the fan trays has been removed from the chassis.
HighBatteryTemperature Provides information that battery temperature is high.
HwComponentFailedCrit Provides information that a critical hardware component of the member has failed.
IncompatControlModule Provides information that an incompatible control module is inserted into the chassis.
IPaddrChange Provides information of the Group IP address change.
ISCSIVolume Provides information when the volume of the iSCSI initiator is modied.
LowAmbientTemp Provides information that one or more sensors are within the critical temperature range.
MultipleRAIDSets Provides information that multiple valid RAID sets are found.
MWKAChange Provides information that MWKA is changed for PS-Series Storage Array.
NVRAMBatteryFailed Provides information that NVRAM battery has failed and the battery is not usable.
OpsPanelFailure Provides information that operations panel is missing or damaged.
PowerSupply Provides information that power supply module has detected a failure.
PowerSupplyFan Provides information that power supply module fan has failed.
RAIDLostCache Provides information that RAID driver is unable to recover the battery-backed cache.
RAIDOrphanCache Provides information that RAID driver found data in the battery-backed cache and does not have
a matching disk array.
RAIDSetDoubleFaulted Provides information that a double fault is detected in the RAID set.
RAIDSetLostBlkTableFull Provides information that RAID lost block table is full.
TempSensorThreshold Provides information that temperature sensor has exceeded the threshold.
DiskStatus Provides information that status of the Dell EMC PS-Series disk has changed.
SCSITgtDevice Provides information that status of the Dell EMC PS-Series SCSI target device has changed.
SCSILuStatus Provides information that status of the Dell EMC PS-Series Logical Unit Number (LUN) has
changed.
ISCSITgtLogin Provides information that the Dell EMC PS-Series iSCSI target device's login attempt failed.
ISCSIIntrLogin Provides information that the initiator's login attempt failed.
ISCSIInstSession Provides information that the active session for a target system or an initiator failed.
iDRAC7, iDRAC8 and iDRAC9 Alert Groups
These alerts are the events generated by Integrated Dell Remote Access Controller 7 (iDRAC7), Integrated Dell Remote Access Controller 8
(iDRAC8) and Dell Remote Access Controller 9(iDRAC9) devices and displayed on the Netcool/OMNIbus console. The following table lists
the iDRAC7, iDRAC8 and iDRAC9 alert groups.
Table 21. iDRAC7, iDRAC8 and iDRAC9 Alert Groups
Alert Group Description
AmperageProbe Provides the amperage details of the system board, disk-drive bay, and the system level.
AutoDiscovery Provides information about the auto discovery conguration execution status.
Using the Dell EMC OpenManage Connection for IBM Tivoli Netcool/OMNIbus 21