Dell EMC OpenManage Connection Version 4.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2011 - 2018 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction....................................................................................................................................................5 2 Prerequisites.................................................................................................................................................. 7 Supported operating systems and requirements for the managing system...............................................................
7 Contacting Dell............................................................................................................................................
1 Introduction This guide provides information about the software requirement, system requirements and the steps to install, configure, and uninstall Dell EMC OpenManage Connection Version 4.0 for IBM Tivoli Netcool/OMNIbus.
Before installing this version of Dell EMC OpenManage Connection for IBM Tivoli Netcool/OMNIbus, download the latest Installation Guide from dell.com/omconnectionsEnterpriseSystemsManagement. For more information about accessing documents, see Accessing Documents From The Dell Support Site - Software.
2 Prerequisites Complete the following prerequisites. Topics: • Supported operating systems and requirements for the managing system • Supported Operating Systems for managed systems • Supported Dell EMC devices and firmware Supported operating systems and requirements for the managing system The following tables lists the operating systems and requirements for integrating the Dell EMC OpenManage Connection on the systems where the Netcool/OMNIbus version 8.1 and 7.4 components are installed: Table 1.
Table 3. IBM Tivoli Netcool/OMNIbus component requirements Component Requirement Purpose Probes Configure the MTTrapd Simple Network Management Protocol (SNMP) probe and the Netcool/OMNIbus Knowledge Library (NcKL). To receive and process the SNMP traps sent by Dell EMC devices. ObjectServer Install and configure the confpack utility. To import Dell EMC integration automation triggers, tools, menus, and conversion classes.
Supported Dell EMC devices and firmware The following table lists the Dell EMC devices and their supported firmware versions for Dell EMC OpenManage Connection. Table 6. Dell EMC devices and firmware Dell EMC Devices Supported OMSA Versions Supported Firmware Versions iDRAC9 NA • • 3.21.23.22 3.21.21.21 iDRAC8 NA • • 2.60.60.60 2.52.52.52 iDRAC7 NA • • 2.60.60.60 2.52.52.52 iDRAC6 Modular NA • • 3.85 3.80 iDRAC6 Monolithic NA • • 2.91 2.90 DRAC5 NA • • 1.6 1.
Dell EMC Devices Supported OMSA Versions Supported Firmware Versions • 3.0 • • 6.1 6.0 Dell EMC M1000e NA Dell EMC Workstations • • • Datacenter Scalable Solutions (DSS 1500 and DSS 2500) NA • • 2.60.60.60 2.52.52.52 Datacenter Scalable Solutions (DSS 1510) NA • • 2.60.60.60 2.52.52.52 Datacenter Scalable Solutions (DSS 9620, DSS 9600 and DSS 9630) NA • • 3.21.23.22 3.21.21.21 PowerVault NX Storage Arrays • • • SC-Series Storage Arrays NA • • 7.2.40.36 7.2.31.
Dell EMC Devices Supported OMSA Versions Supported Firmware Versions • • 6.5.2.5 6.3.3.14 W-Series Dell EMC Precision Workstation • • • 9.2.1 9.2 9.1 • W-Series Mobility Controllers (6.4) • NA NOTE: Dell EMC Workstations refers to Dell EMC Precision R7910 and R7920 Rack Workstations.
3 Installing Dell EMC OpenManage Connection for Netcool/OMNIbus To install Dell EMC OpenManage Connection for Netcool/OMNIbus, you must extract the component-specific files on the systems where you have installed the Netcool/OMNIbus components and deploy them. For more information on extracting component-specific files, see Integration Details for Netcool/OMNIbus Components.
Integration details for Netcool/OMNIbus components The following table lists the Netcool/OMNIbus components and the Integration folders for Dell EMC OpenManage Connection. Deploy the integration files of Dell EMC OpenManage Connection from the corresponding folder to the Netcool/OMNIbus components folder. Table 7. Netcool/OMNIbus Components Component Integration Folders probe_integration Contains the rules and lookup table files for the supported Dell EMC devices.
OOB Server (iDRAC9, DRAC8, iDRAC7) traps a Uncomment the dell-IDRAC-MIB.include.snmptrap.lookup file include statement in the dell.master.include.lookup file. b Uncomment the dell-IDRAC-MIB.include.snmptrap.rules file include statement in the dell.master.include.rules file. FX2 CMC, VRTX CMC, CMC, iDRAC6, DRAC5 traps a Uncomment the dell-RAC-MIB.include.snmptrap.lookup file include statement in the dell.master.include.lookup file. b Uncomment the dell-RAC-MIB.include.snmptrap.
2 • • Uncomment the dell.Nseriesswitch.master.include.rules file include statement in the dell.master.include.rules file. W-Series Switches 1 Uncomment the dell.Wseriesswitch.master.include.lookup file include statement in the dell.master.include.lookup file. 2 Uncomment the dell.Wseriesswitch.master.include.rules file include statement in the dell.master.include.rules file. Management Systems 1 Uncomment the dell-NGM-MIB.include.snmptrap.lookup file include statement in the dell.master.include.
• On systems running 64–bit Linux: $OMNIHOME/bin/nco_confpack -import -server -user -password -package /delldevice_confpack_64bit_v_4_0.jar • On systems running Windows: %OMNIHOME%\bin\nco_confpack.bat -import -server -user password -package \delldevice_confpack_64bit_v_4_0.jar NOTE: By default, the ObjectServer is NCOMS. 2 Navigate to opt/IBM/Tivoli/Netcool/OMNIbus/bin and run .
4 Click the executable tab and edit the following URL by providing the IP address and the port number for OME: https:// For example: https://11.95.145.156:2607/ For more information, see the OpenManage Enterprise User's Guide at dell.com/support/home. Configuring PowerVault Modular Disk Storage Manager console on the ObjectServer The PowerVault Modular Disk Storage Manager (MDSM) console uses the configured URL to launch the console in a separate window.
Configuring Dell EMC AirWave Management Platform console on the ObjectServer The Dell EMC AirWave Management Platform console uses the configured URL to launch the console in a default browser. To configure the Dell EMC AirWave Management Platform console URL on systems running Windows and Linux: 1 Provide the required security credentials to access the OMNIbus ObjectServer and log in to the ObjectServer. 2 In the Configuration window, select Menu > Tools.
3 Add an environment variable named OMNIBROWSER and set it to the path of the default or desired browser. NOTE: This is applicable to systems running Windows and Linux. Using the Dell EMC ConfigUtility for Desktop To use the Dell EMC ConfigUtility to set the SNMP community string, WSMan parameters, and the TIPJAVAHOME parameters for the Desktop: 1 Navigate to the %OMNIHOME% directory on the system where the Desktop component is installed.
On systems running Windows: %NCHOME%\platform\\jre_1.6.7\jre\bin\java -Ddell.config.path=desktop jar dell_OMC_ITNO_ConfigUtility_v_4_0.jar -tipjavahome= On systems running Linux: $NCHOME/platform//jre_1.6.7/jre/bin/java -Ddell.config.path=desktop jar dell_OMC_ITNO_ConfigUtility_v_4_0.
• snmp4j-2.6.2.jar • SYMsdk.jar • vrtxcmclauncher_linux.cgi • vrtxcmclauncher_nt.cgi • warranty_linux.cgi • warranty_nt.cgi To deploy the Dell EMC integration components on the system that hosts the web GUI: 1 By default, the web GUI is installed in C:\IBM\netcool \omnibus_webgui folder or C:\IBM\netcool\omnibus\omnibus_webgui folder. If your installation directory is in a different location, you need to add the OMNIWEBGUI environment variable in the web GUI installed directory.
to datasource="" a For IBM Tivoli Netcool/OMNIbus 8.1: On systems running Windows: \waapi\bin\runwaapi -host -user password -file export.xml On systems running Linux: b /waapi/bin/runwaapi -host -user password -file export.xml For IBM Tivoli Netcool/OMNIbus 7.4: On systems running Windows: \waapi\bin\runwaapi -host
On systems running Windows: \java_1.7_64\jre\bin\java -Ddell.config.path=webgui -jar dell_OMC_ITNO_ConfigUtility_v_4_0.jar –wsmanusername=root –wsmanpassword On systems running Linux: b /java_1.7_64/jre/bin/java -Ddell.config.path=webgui -jar dell_OMC_ITNO_ConfigUtility_v_4_0.jar –wsmanusername=root –wsmanpassword For IBM Tivoli Netcool/OMNIbus 7.4: On systems running Windows: \java\jre\bin\java -Ddell.config.
To configure a Dell EMC console launch tool on a system running Linux: 1 Log in to the web GUI on a system running Linux. 2 Click Administration > Event Management Tools > Tool Creation. NOTE: For Netcool OMNIbus version 8.1, you will have to select Tool Configuration. 3 Double-click on the Dell EMC console that you want to launch. 4 Modify the name of the CGI Script or the URL based on the Dell EMC console you want to launch.
4 Edit the following URL by providing the IP address and the port number: https://:/ omalogin.html?managedws=false&mnip=@Node For example: https://11.95.145.156:1311/omalogin.html?managedws=false&mnip=@Node For more information, see the Dell EMC Server Administrator documentation at dell.com/support/home.
3 Select DellEMCOpenManageNetworkManagerConsole on the right pane to launch the Tool Configuration window. 4 Edit the following URL by providing the IP address and the port number for OMNM: http://OMNM_IP_Address_OR_Host:OMNM_Port For example: http://192.168.10.12:8080 For more information, see the OpenManage Essentials User's Guide at dell.com/support/home.
4 Upgrading Dell EMC OpenManage Connection for Netcool/OMNIbus To upgrade the Dell EMC OpenManage Connection for Netcool/OMNIbus: 1 Uninstall the existing connection. For more information, see the Dell EMC OpenManage Connection for Netcool/OMNIbus Installation Guide, for the existing version, at dell.com/omconnectionsEnterpriseSystemsManagement. 2 Install the latest version using the installation procedure described in Installing Dell EMC OpenManage Connection for Netcool/ OMNIbus.
5 Uninstalling Dell EMC OpenManage Connection for Netcool/OMNIbus To uninstall Dell EMC OpenManage Connection for Netcool/OMNIbus you must uninstall or remove the component-specific files. Topics: • Uninstalling Probe Integration • Uninstalling ObjectServer Integration • Uninstalling Desktop Integration • Uninstalling Web GUI Integration Uninstalling Probe Integration To uninstall the Probe integration: 1 2 Navigate to $NC_RULES_HOME\snmptrap-rules.
• Dell EMC Warranty Report • Dell EMC OpenManage Enterprise Console • Dell EMC Server Trap Configuration Information NOTE: Dell EMC OpenManage Enterprise Console is only applicable for systems running on Linux Operating System. 4 In the Configuration window, select Menu > Menus. 5 Under the Alerts Menu, select Dell EMC Tools. 6 Right-click Dell EMC Tools and click Delete.
• Remove the file delldevice_int_desktop.ver • All Desktop Integration — Remove the following files: – dell_config.properties – dell_MD_Array_Common.jar – dell_OMNIbus_Connection_KB_Tool_v_4_0.jar – dell_OMC_ITNO_Helper_v_4_0.jar – dell_OMC_ITNO_ConfigUtility_v_4_0.jar – intel_wsman_v_1_0_1.jar – snmp4j-2.6.2.jar – SYMsdk.jar Uninstalling Web GUI Integration To uninstall the web GUI integration: 1 Login to the web GUI. 2 Remove the following files from the webgui_integration folder. • dell_config.
9 • draclauncher_linux.cgi • draclauncher_nt.cgi • cmclauncher_linux.cgi • cmclauncher_nt.cgi • compellent_linux.cgi • compellent_nt.cgi • eqllauncher_linux.cgi • eqllauncher_nt.cgi • n_switchadminlauncher_linux.cgi • n_switchadminlauncher_nt.cgi • omsalauncher_linux.cgi • omsalauncher_nt.cgi • warranty_linux.cgi • warranty_nt.cgi • kblauncher_linux.cgi • kblauncher_nt.cgi Restart the Web GUI component.
6 Accessing documents from the Dell EMC support site You can access the required documents using the following links: • For Dell EMC Enterprise Systems Management documents — www.dell.com/esmmanuals • For Dell EMC OpenManage documents — www.dell.com/openmanagemanuals • For Dell EMC Remote Enterprise Systems Management documents — www.dell.com/esmmanuals • For iDRAC and Dell Lifecycle Controller documents — www.dell.
7 Contacting Dell NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues: 1 Go to Dell.com/support. 2 Select your support category.