Users Guide
Table Of Contents
- Dell EMC OpenManage Ansible Modules Version 4.0.0 User’s Guide
- Contents
- Overview
- Getting Started
- Modules for iDRAC
- How OpenManage Ansible Modules work with iDRAC
- Running your first iDRAC Playbook
- Updating Firmware
- Configuring PowerEdge Servers
- Deploying operating system
- Server Inventory
- Server administration tasks
- Storage controller
- Modules for OpenManage Enterprise (OME)
- How OpenManage Ansible Modules work with OME
- Running your first OME Playbook
- Manage Devices
- Manage device configuration templates
- Template Service
- Manage the device firmware
- Manage jobs
- Manage users
- Manage identity pool
- Manage application settings
- Manage network configuration
- Manage fabrics
- Manage Profiles
- Device discovery
- Manage Chassis
- Manage Active Directory service and user groups
- Diagnostics
- Modules for Redfish APIs
- Deprecated modules
}
}
Examples
- name: Assign a dedicated hot spare
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
volume_id: "Disk.Virtual.0:RAID.Slot.1-1"
target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
tags:
- assign_dedicated_hot_spare
- name: Assign a global hot spare
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
tags:
- assign_global_hot_spare
- name: Set a controller encryption key
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
command: "SetControllerKey"
controller_id: "RAID.Slot.1-1"
key: "PassPhrase@123"
key_id: "mykeyid123"
tags:
- set_controller_key
- name: Rekey in LKM mode
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
command: "ReKey"
controller_id: "RAID.Slot.1-1"
key: "PassPhrase@123"
key_id: "mykeyid123"
old_key: "OldPassPhrase@123"
tags:
- rekey_lkm
- name: Rekey in SEKM mode
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
command: "ReKey"
controller_id: "RAID.Slot.1-1"
mode: "SEKM"
tags:
- rekey_sekm
- name: Remove the controller key
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
command: "RemoveControllerKey"
controller_id: "RAID.Slot.1-1"
tags:
- remove_controller_key
- name: Reset configuration
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"