Release Notes
Table Of Contents
- Dell EMC OpenManage Ansible Modules Version 4.0.0 Release Notes
- Priority and recommendations
- Revision history
- Product description
- New features
- Changed features
- Resolved issues
- Known Issues
- Limitations
- Environment and system requirements
- Installation and upgrade consideration
- Related documentation
- Where to get help
Functional area Module Description
● This module is updated to support
repositories that are available on the
Dell support site.
Modules for OpenManage Enterprise and
OpenManage Enterprise Modular
ome_template_network_vlan
This module is updated with an input
option, which allows you to apply the
modified VLAN settings immediately on
the associated servers in the modular
system.
Modules for OpenManage Enterprise
ome_device_group
This module is updated to support
adding devices to a group using the IP
addresses of the devices and group ID.
Resolved issues
Functional area Description
Modules for iDRAC The dellemc_idrac_storage_volume module fails if the Block Size, Free Size,
or Size state of the physical disk is "Not Available".
Modules for iDRAC Proper error message is not shown if invalid share details are provided in iDRAC
modules.
Modules for iDRAC The idrac_firmware module reports error when no updates required from
network share (CIFS or NFS) based catalog for iDRAC9 based servers.
Modules for OpenManage Enterprise
and OpenManage Enterprise Modular
The ome_firmware_baseline module fails to retrieve device by using the device
ID if the device ID is not in the first 50 device IDs.
Modules for OpenManage Enterprise
Modular
Unable to propagate VLAN settings on OME-M by using
ome_template_identity_pool and ome_template_network_vlan
modules.
Modules for OpenManage Enterprise
Modular
Unable to perform Fabric management on some systems by using
ome_smart_fabric module.
Modules for OpenManage Enterprise
Modular
The ome_smart_fabric module is not idempotent during the smart fabric
configuration on some systems.
Known Issues
Functional area
Description Workaround/Resolution (Optional)
Modules for iDRAC Firmware update may fail if multiple
DUPs are uploaded. Local DUPs are
stored in a temporary folder that
is created by a scratch-pad. The
capacity of this folder is only 300
MB.
Ensure that the combined size of all the DUPs is
less than 300 MB.
Modules for iDRAC If the controller does not support
updating the EncryptionTypes
parameter, a default value is
automatically set during the storage
volume create operation and the
storage volume modify operation
fails.
None
Modules for iDRAC Redfish Storage Volume operations
sometime return an operation
progress percentage different than
the actual job status.
It is recommended to wait for a few seconds to
allow the job to reflect the actual status.
3