Users Guide
Table Of Contents
- Dell EMC OpenManage Ansible Modules Version 2.0.1 User’s Guide
- Overview
- Getting Started
- Modules for iDRAC
- Modules for OpenManage Enterprise (OME)
- Troubleshooting
- Accessing documents from the Dell EMC support site
- Name : "NIC.Integrated.x-x-x"
Enabled : True
- name: Configure Boot Sources - Index
dellemc_configure_bios:
idrac_ip: "xx.xx.xx.xx"
idrac_user: "xxxx"
idrac_password: "xxxxxxxx"
boot_sources:
- Name : "NIC.Integrated.x-x-x"
Index : 0
Configure RAID
Module: dellemc_configure_raid
Synopsis
This module hosts the RAID configuration related attributes.
NOTE: This module is deprecated and replaced with dellemc_idrac_storage_volume.
Options
Table 27. dellemc_configure_raid
Parameter/aliases Required Default Choices Comments
idrac_ip Yes NA NA iDRAC IP Address
idrac_user Yes NA NA iDRAC username
idrac_pwd Yes NA NA iDRAC user password
idrac_port No 443 NA iDRAC port
share_name Yes NA NA
CIFS or NFS Network share or a
local path
share_user No NA NA
Network share user in the format
'user@domain' or 'domain\user' if
user is part of a domain else 'user'.
This option is mandatory for CIFS
Network share.
share_pwd No NA NA
Network share user password.
This option is mandatory for CIFS
Network share.
share_mnt No NA NA
Local mount path of the network
share with read-write permission
for Ansible user. This option is
mandatory for Network share.
vd_name No NA NA
Virtual disk name
● Optional, if we perform create
operations
● Mandatory, if we perform
remove operations
span_depth No 1 NA Span Depth
span_length No 2 NA Span Length
number_dedicated_hot_spar
e
No 0 NA Number of Dedicated Hot Spare
number_global_hot_spare No 0 NA Number of Global Hot Spare
Modules for iDRAC 35