Users Guide
Table Of Contents
- Dell EMC OpenManage Ansible Modules Version 2.0 User’s Guide
- Overview
- Getting Started
- Modules for iDRAC
- How OpenManage Ansible Modules for iDRAC works
- Running your first iDRAC Playbook
- Updating Firmware
- Configuring PowerEdge Servers
- Deploying operating system
- Server Inventory
- Server administration tasks
- Modules for OpenManage Enterprise (OME)
- Troubleshooting
- Accessing documents from the Dell EMC support site
Table 25. dellemc_configure_raid (continued)
Parameter Required Default Choices Comments
● If the value is 'absent', the
module will perform 'remove'
operations
Table 26. Return Values
Name Description Returned Type Sample
RAID
configuration
Configures the RAID
configuration attributes
Success String
https://github.com/dell/Dell-EMC-Ansible-
Modules-for-iDRAC/blob/master/samples/
dellemc_configure_raid.md
Example
-name: Configure the RAID attributes
dellemc_configure_raid:
idrac_ip: "xx.xx.xx.xx"
idrac_user: "xxxx"
idrac_pwd: "xxxxxxxx"
share_name: "xx.xx.xx.xx:/share"
share_pwd: "xxxxxxxx"
share_user: "xxxx"
share_mnt: "xxxxxx"
controller_fqdd: "xxxxxxxx"
vd_name: "xxxxxx"
Configure storage volume
Module: dellemc_idrac_storage_volume
Synopsis
This module hosts the RAID configuration related attributes.
Check_mode support: Yes
Options
Table 27. dellemc_idrac_storage_volume
Parameter Required Default Choices Comments
idrac_ip Yes NA NA iDRAC IP Address
idrac_user Yes NA NA iDRAC username
idrac_pwd Yes NA NA iDRAC user password
idrac_port No 443 NA iDRAC port
span_depth No 1 NA Span Depth
span_length No 1 NA Span Length
number_dedicated_hot
_spare
No 0 NA Number of Dedicated Hot Spare
volume_type No RAID 0
● RAID 0
● RAID 1
● RAID 5
● RAID 6
● RAID 10
● RAID 50
● RAID 60
Provide the required RAID level