Table 25. dellemc_idrac_storage_volume (continued)
Parameter Required Default Choices Comments
idrac_port No 443 NA iDRAC port
span_depth No 1 NA Span Depth
span_length No 1 NA Span Length
number_dedicated_hot
_spare
No 0 NA Number of Dedicated Hot Spare
volume_type No RAID 0
● RAID 0
● RAID 1
● RAID 5
● RAID 6
● RAID 10
● RAID 50
● RAID 60
Provide the required RAID level
disk_cache_policy No Default
● Default
● Enabled
● Disabled
Disk Cache Policy
write_cache_policy No WriteThrough
● WriteThrough
● WriteBack
● WriteBackForce
Write Cache Policy
read_cache_policy No NoReadAhead
● NoReadAhead
● ReadAhead
● AdaptiveReadAhea
d
Read Cache Policy
stripe_size No 65536 NA Provide stripe size value in multiples of 64
* 1024
controller_id No NA NA Fully Qualified Device Descriptor (FQDD)
of the storage controller, for example:
RAID.Integrated.1-1
NOTE: Controller FQDD is required for
C(create) RAID configuration.
volume_id No NA NA Fully Qualified Device Descriptor (FQDD)
of the virtual disk, for example:
Disk.virtual.0:RAID.Slot.1-1
NOTE: This option is used to get the
virtual disk information.
media_type No None
● HDD
● SDD
Media type
protocol No None
● SAS
● SATA
Bus protocol
state Yes view
● create
● delete
● view
● If C(create), the module will perform
create operations
● If C(delete), the module will perform
remove operations
● If C(view), the module will return
storage view
volumes No NA NA A list of virtual disk-specific iDRAC
attributes. This is applicable for C(create)
and C(delete) operations.