Users Guide

Table 23. dellemc_configure_raid (continued)
Parameter Required Default Choices Comments
Adaptive
stripe_size No 65536 NA
Provide stripe size value in
multiples of 64 * 1024
controller_fqdd Yes NA NA
Fully Qualified Device Descriptor
(FQDD) of the storage controller,
for e.g. RAID.Integrated.1-1
media_type No HDD
HDD
SSD
Media type
bus_protocol No SATA
SAS
SATA
Bus protocol
state Yes NA
present
absent
If the value is 'present', the
module will perform 'create'
operations
If the value is 'absent', the
module will perform 'remove'
operations
Table 24. Return Values
Name Description Returned Type Sample
RAID
configuration
Configures the RAID
configuration attributes
Success String
https://github.com/dell/Dell-EMC-Ansible-
Modules-for-iDRAC/blob/master/samples/
dellemc_configure_raid.md
Example
-name: Configure the RAID attributes
dellemc_configure_raid:
idrac_ip: "xx.xx.xx.xx"
idrac_user: "xxxx"
idrac_pwd: "xxxxxxxx"
share_name: "xx.xx.xx.xx:/share"
share_pwd: "xxxxxxxx"
share_user: "xxxx"
share_mnt: "xxxxxx"
controller_fqdd: "xxxxxxxx"
vd_name: "xxxxxx"
Configuring storage volume
Module: dellemc_idrac_storage_volume
Synopsis
This module hosts the RAID configuration related attributes.
Check_mode support: Yes
Options
Table 25. dellemc_idrac_storage_volume
Parameter Required Default Choices Comments
idrac_ip Yes NA NA iDRAC IP Address
idrac_user Yes NA NA iDRAC username
idrac_pwd Yes NA NA iDRAC user password
Configuring PowerEdge Servers 27