Users Guide
idrac_pwd: "xxxxx"
idrac_port: "xxx"
Congure System Lockdown Mode
Module: dellemc_system_lockdown_mode
Synopsis
System Lockdown Mode provides a mechanism to protect conguration from any unintentional or accidental changes after the system is
provisioned to a certain level.
This module is responsible for enabling or disabling the lockdown mode of a system. When System Lockdown Mode is enabled, the
system’s conguration is locked and system cannot be congured or updated until the lockdown mode is disabled.
Check_mode support: No
Options
Table 48. dellemc_system_lockdown_mode
Parameter Required Default Choices Comments
idrac_ip Yes NA NA iDRAC IP Address
idrac_user Yes NA NA iDRAC username
idrac_pwd Yes NA NA iDRAC user password
idrac_port No 443 NA iDRAC port
share_name Yes NA NA CIFS or NFS network share or a local path
share_user No NA NA
Network share user in the format 'user@domain'
or user\domain if user is part of a domain else
'user'. This eld is mandatory for CIFS Network
Share.
share_pwd No NA NA
Network share user password. This eld is
mandatory for CIFS Network Share.
share_mnt No NA NA
Local mount path of the network share with read-
write permission for Ansible user. This option is
mandatory for CIFS or NFS Network share.
lockdown_mode Yes NA
• Enabled
• Disabled
Whether to Enable or Disable system lockdown
mode
Table 49. Return Values
Name Description Returned Type Sample
System Lockdown
Mode
Congures lockdown
mode of the system
Success String
https://github.com/dell/Dell-EMC-Ansible-Modules-for-
iDRAC/blob/master/samples/
dellemc_system_lockdown_mode.md
Example
-name: Configure System Lockdown Mode
dellemc_system_lockdown_mode:
Modules for iDRAC