Users Guide

idrac_ip: "192.168.0.1"
idrac_user: "username"
idrac_password: "password"
state: "delete"
volumes:
- name: "volume_1"
-name: Delete multiple volume
dellemc_idrac_storage_volume:
idrac_ip: "192.168.0.1"
idrac_user: "username"
idrac_password: "password"
state: "delete"
volumes:
- name: "volume_1"
- name: "volume_2"
Congure Collect System Inventory on Restart
Module: dellemc_idrac_lc_attributes
Synopsis
This module is responsible for enabling or disabling of Collect System Inventory on Restart (CSIOR) property for all iDRAC or LC jobs.
When you enable the
CSIOR property, hardware inventory and part conguration information are discovered and compared with previous
system inventory information on every system restart.
Check_mode support: Yes
Options
Table 30. dellemc_idrac_lc_attributes
Parameter/aliases Required Default Choices Comments
idrac_ip Yes NA NA iDRAC IP Address
idrac_user Yes NA NA iDRAC username
idrac_password/
idrac_pwd
Yes NA NA iDRAC user password
idrac_port No 443 NA iDRAC port
share_name Yes NA NA CIFS or NFS network share or a local path
share_user No NA NA
Network share user in the format 'user@domain'
or 'domain\user' if user is part of a domain else
'user'. This option is mandatory for CIFS Network
share.
share_password/
share_pwd
No NA NA
Network share user password. This option is
mandatory for CIFS Network share.
share_mnt No NA NA
Local mount path of the network share with
read-write permission for Ansible user. This option
is mandatory for CIFS or NFS Network share.
csior Yes NA
Enabled
Disabled
Whether to Enable or Disable Collect System
Inventory on Restart (CSIOR) property for all
iDRAC or LC jobs
42 Modules for iDRAC