Users Guide
This module hosts the RAID conguration related attributes.
Check_mode support: Yes
Options
Table 25. dellemc_idrac_storage_volume
Parameter Required Default Choices Comments
idrac_ip Yes NA NA iDRAC IP Address
idrac_user Yes NA NA iDRAC username
idrac_pwd Yes NA NA iDRAC user password
idrac_port No 443 NA iDRAC port
span_depth No 1 NA Span Depth
span_length No 1 NA Span Length
number_dedicated_hot_s
pare
No 0 NA Number of Dedicated Hot Spare
volume_type No RAID 0
• RAID 0
• RAID 1
• RAID 5
• RAID 6
• RAID 10
• RAID 50
• RAID 60
Provide the required RAID level
disk_cache_policy No Default
• Default
• Enabled
• Disabled
Disk Cache Policy
write_cache_policy No WriteThrough
• WriteThrough
• WriteBack
• WriteBackForce
Write Cache Policy
read_cache_policy No NoReadAhead
• NoReadAhead
• ReadAhead
• AdaptiveReadAhead
Read Cache Policy
stripe_size No 65536 NA Provide stripe size value in multiples of 64 *
1024
controller_id No NA NA Fully Qualied Device Descriptor (FQDD) of
the storage controller, for example:
RAID.Integrated.1-1
NOTE: Controller FQDD is required for
C(create) RAID conguration.
Conguring PowerEdge Servers 31