Users Guide

Table 15. dellemc_congure_idrac_eventing
Parameter Required Default Choices Comments
idrac_ip Yes NA NA iDRAC IP Address
idrac_user Yes NA NA iDRAC username
idrac_pwd Yes NA NA iDRAC user password
idrac_port No 443 NA iDRAC port
share_name Yes NA NA
CIFS or NFS Network share or a local
path
share_user No NA NA
Network share user in the format
'user@domain' or 'domain\user' if user is
part of a domain else 'user'. This option
is mandatory for CIFS Network share.
share_pwd No NA NA
Network share user password. This
option is mandatory for CIFS Network
share.
share_mnt No NA NA
Local mount path of the network share
with read-write permission for Ansible
user. This option is mandatory for CIFS
or NFS Network share.
destination_number No None NA Destination number for SNMP Trap
destination No None NA Destination for SNMP Trap
snmp_v3_username No NA NA SNMP v3 username for SNMP Trap
snmp_trap_state No NA
Enabled
Disabled
Whether to Enable or Disable SNMP
alert
email_alert_state No NA
Enabled
Disabled
Whether to Enable or Disable Email alert
alert_number No None NA Alert number for Email conguration
address No NA NA Email address for SNMP Trap
custom_message No NA NA
Custom message for SNMP Trap
reference
enable_alerts No NA
Enabled
Disabled
Whether to Enable or Disable iDRAC
alerts
authentication No NA
Enabled
Disabled
Simple Mail Transfer Protocol
Authentication
smtp_ip_address No NA NA SMTP IP address for communication
smtp_port No None NA SMTP Port number for access
username No None NA Username for SMTP authentication
Conguring PowerEdge Servers 19