Users Guide
Check_mode support: No
Options
Table 9. dellemc_import_server_cong_prole
Parameter Required Default Choices Comments
end_host_power_state No On
• On
• O
• If On, End host power is on
• If O, End host power is o
idrac_ip Yes NA NA iDRAC IP Address
idrac_user Yes NA NA iDRAC username
idrac_pwd Yes NA NA iDRAC user password
idrac_port No 443 NA iDRAC port
job_wait Yes NA
• True
• False
• If the value is True, it waits for the SCP
import job to nish and returns the job
completion status
• If the value is False, it returns immediately
with a JOB ID after queuing the SCP
import job in LC job queue
scp_components No ALL
• ALL
• iDRAC
• BIOS
• NIC
• RAID
• If ALL, the module imports all components
congurations from SCP le
• If iDRAC, the module imports iDRAC
conguration from SCP le
• If BIOS, the module imports BIOS
conguration from SCP le
• If NIC, the module imports NIC
conguration from SCP le
• If RAID, the module imports RAID
conguration from SCP le
scp_le Yes NA NA Server Conguration Prole le name
share_name Yes NA NA Network share or a local path
share_user No NA NA
Network share user in the format
'user@domain' or 'domain\user' if user is part
of a domain else 'user'. This option is
mandatory for CIFS Network share.
share_pwd No NA NA
Network share user password. This option is
mandatory for CIFS Network share.
shutdown_type No Graceful
• Graceful
• Forced
• NoReboot
• If Graceful, it gracefully shuts down the
server
• If Forced, it forcefully shuts down the
system
• If NoReboot, it does not reboot the server
14 Conguring PowerEdge Servers