Users Guide

number_global_hot_spare No 0 NA Number of Global Hot Spare
raid_level No RAID 0
RAID 0
RAID 1
RAID 5
RAID 6
RAID 10
RAID 50
RAID 60
Provide the required RAID level
disk_cache_policy No Default
Default
Enabled
Disabled
Disk Cache Policy
write_cache_policy No WriteThrough
WriteThrough
WriteBack
WriteBackForce
Write cache policy
read_cache_policy No NoReadAhead
NoReadAhead
ReadAhead
Adaptive
Read cache policy
stripe_size No 65536 NA
Provide stripe size value in multiples
of 64 * 1024
controller_fqdd Yes NA NA
Fully Qualied Device Descriptor
(FQDD) of the storage controller, for
e.g. RAID.Integrated.1-1
media_type No HDD
HDD
SSD
Media type
bus_protocol No SATA
SAS
SATA
Bus protocol
state Yes NA
present
absent
If the value is 'present', the
module will perform 'create'
operations
If the value is 'absent', the module
will perform 'remove' operations
Table 24. Return Values
Name Description Returned Type Sample
RAID
conguration
Congures the RAID conguration
attributes
Success String
https://github.com/dell/Dell-EMC-Ansible-
Modules-for-iDRAC
Example
-name: Configure the RAID attributes
dellemc_configure_raid:
idrac_ip: "xx.xx.xx.xx"
26
Conguring PowerEdge Servers