vlan_priority: "1"
enable_nic: "Enabled"
nic_selection: "Dedicated"
failover_network: "T_None"
auto_detect: "Disabled"
auto_negotiation: "Enabled"
network_speed: "T_1000"
duplex_mode: "Full"
nic_mtu: "1500"
ip_address: "x.x.x.x"
enable_dhcp: "Enabled"
dns_1: "x.x.x.x"
dns_2: "x.x.x.x"
dns_from_dhcp: "Enabled"
enable_ipv4: "Enabled"
gateway: "None"
net_mask: "None"
static_dns_1: "x.x.x.x"
static_dns_2: "x.x.x.x"
static_dns_from_dhcp: "Enabled"
static_gateway: "None"
static_net_mask: "None"
Conguring BIOS
Module: dellemc_congure_bios
Synopsis
This module hosts the BIOS conguration related tasks. The tasks are:
• Setup_boot_mode: Congures the boot mode to BIOS or Unied Extensible Firmware Interface (UEFI).
• Setup_onetime_boot_mode: Congures the one time boot mode setting such as Disabled, OneTimeBootSeq, OneTimeHddSeq,
OneTimeUeBootSeq.
• Setup_NVMe_Mode: Congures the NVMe mode.
• Setup_Secure_boot_Mode: Congures how the BIOS uses the Secure Boot Policy Objects.
Options
Table 21.
dellemc_congure_bios
Parameter Required Default Choices Comments
idrac_ip Yes NA NA iDRAC IP Address
idrac_user Yes NA NA iDRAC username
idrac_pwd Yes NA NA iDRAC user password
idrac_port No 443 NA iDRAC port
share_name Yes NA NA
CIFS or NFS network
share or a local path
share_user No NA NA
Network share user in the
format 'user@domain' if
user is part of a domain
else 'user'
share_pwd No NA NA
Network share user
password