+ Checking IC Current Monitor 0x40 ..... Passed
+ Checking FAN Controller 0x1b ..... Passed
I2C Devices: Overall test results------------------ >>>> PASSED
Testing Temp sensor devices:
+ Checking [Sensor 0] = 39.0 C ....................... Passed
Temp Sensors: Overall test results------------------ >>>> PASSED
PL Tool test:
System CPLD: SFP LED Link Status Register Reg Addr: 0x15 ...............Passed
PL Tool: Overall test results------------------ >>>> PASSED
Fan Controller Short test: Overall test results------------------ >>>> PASSED
fan1 speed is 8600 RPM
fan2 speed is 8650 RPM
Show Optics in System
Port # Name Status Type Part Number Rev Serial Number
------ ------------ ------ ------- --------------- --- ---------------
1 SFP 1 REMOVED
2 SFP 2 REMOVED
Testing Memory Regions:
Testing Memory Region 0:
Address Read Test ......................................... Passed
Address Write Test ........................................ Passed
Address Walking 1's Test .................................. Passed
Address Walking 0's Test .................................. Passed
Data Read Test ............................................ Passed
Data Write Test ........................................... Passed
Data Walking 1's Test ..................................... Passed
Data Walking 0's Test ..................................... Passed
Data Sliding 1's Test ..................................... Passed
Data Sliding 0's Test ..................................... Passed
Data Pattern Test ......................................... Passed
Testing Memory Region 1:
Address Read Test ......................................... Passed
Address Write Test ........................................ Passed
Address Walking 1's Test .................................. Passed
Address Walking 0's Test .................................. Passed
Data Read Test ............................................ Passed
Data Write Test ........................................... Passed
Data Walking 1's Test ..................................... Passed
Data Walking 0's Test ..................................... Passed
Data Sliding 1's Test ..................................... Passed
Data Sliding 0's Test ..................................... Passed
Data Pattern Test ......................................... Passed
Memory: Overall test results------------------ >>>> PASSED
MAC Addr Test: Overall test results------------------ >>>> PASSED
/dev/mmcblk0p2 / ext4Mounted
Filesystem Devices:******************************
Diagnostics Application ******************************
DellEmc Diag edatool version 1.4, package 3.43.4.81-19 2020/05/14
EDA: Overall test results ----------------------------- >>> Passed
root@dellemc-diag-os:~#
edatool log (for ADVA ready system configurations)
NOTE:
The following output is specific for the VEP1405 series of systems that are ADVA ready. For detailed configuration
information, see the Virtual Edge Platform 1405 Series Getting Started Guide.
root@dellemc-diag-os:~# edatool
*****************************
* Diagnostics Application *
*****************************
DellEmc Diag edatool version 1.4, package 3.43.4.81-19 2020/05/1
BIOS version:
3.48.0.9-11
CPLD version:
4