Release Notes

Electrical, power, and cooling
Power supplies
The VEP1405 supports one external AC/DC power supply with secure locking thread.
Table 10. Power specifications
Parameter Specification
Power input AC: 100 VAC240 VAC, 50/60 Hz
Max current draw per system - AC
100 VAC: 2.0A
240 VAC: 1.0A
Power output 12 V DC, 5.4A (65 W)
Power consumption
1425 20 W typical, 30 W max
1445 35 W typical, 45 W max
1485 40 W typical, 50 W max
Power availability for optics Power per SFP+ Port 1 W
Cooling
Table 11. Cooling specifications
Parameter Specification
Thermal dissipation See the Power consumption information in the Product specifications section
Number of fixed fans 1 (1425) or 2 (1445 and 1485)
Minimum CFM 5.6 (one fan)
Maximum CFM 10 (two fans)
NOTE: For thermal considerations, do not stack the VEP1405 platforms on top of each other. Stacking of the platforms
impairs cooling and places the external power supply on top of the unit.
Environmental
Table 12. Environmental specifications
Parameter Specifications
Operating temperature 0°C-40°C (32°F-104°F)
Storage temperature -40°C to 70°C (-40°F to 158°F)
Operating relative humidity
5% to 85% (RH), noncondensing continuously
5% to 90% (RH), noncondensing Short term (< 1% of operational hour per
year)
Storage relative humidity 5% to 90% (RH), noncondensing
Operating altitude Maximum Operating altitude: 10,000 ft Temperature and performance derating
above 950 m (3,117 ft) per Dell Enterprise Reliability Engineering (A09)
specification
Storage altitude 10,668 m (35,000 ft)
System overview 15