Table 5. Back view system status indicator LED behavior
Class Behavior
1000M Base-T LED
Link LED - Green or amber
Solid green - Port is linked and running at maximum 1000M
speed on Base-T port
Solid amber - Port is linked and running at lower 100M or 10M
speed on Base-T port
Off - No link
Activity LED - Green
NOTE: The LED flashes green during port activity.
Off - no port activity
SFP+ LED
Link LED - Green or amber
Solid green - Port is linked and running at 10G speed
Solid amber - Port is linked and running at 1G speed
Off - No link
Activity LED - Green
NOTE: The LED flashes green during port activity.
Off - no port activity
Table 6. Reset button behavior
Action Behavior
Press the Reset button for less than 5 seconds:
System reboots
Press the Reset button for more than 5 seconds:
System reboots and system is reset to factory defaults
Status indicator LED color changes to blue
Flag indicating a long push is set by the BIOS in the CMOS RAM
Flag allows user to have the operating system detect a long button
push
Table 7. Chassis physical design
Parameter Configuration option 1 Configuration option 2
Height 5.2 cm (2.0 in) 5.2 cm (2.0 in)
Width 20.8 cm (8.1 in) 20.8 cm (8.1 in)
Depth 20.0 cm (7.9 in) 20.0 cm (7.9 in)
Chassis weight with factory-
installed components
4-core: 1.44 kg (3.17 lb)
8-core: 1.42 kg (3.13 lb)
16-core: 1.44 kg (3.17 lb)
8-core: 1.42 kg (3.13 lb)
16-core: 1.44 kg (3.17 lb)
NOTE: Chassis weight does not include the weight of the power supply.
Table 8. Environmental parameters
Parameter Configuration option 1 Configuration option 2
Operating temperature 040°C (32°F104°F) continuously 040°C (32°F104°F) continuously
Operating humidity
5% to 85% (RH), noncondensing
continuously
5% to 90% (RH), noncondensing short-
term (< 1% of operational hour per year)
5% to 85% (RH), noncondensing
continuously
5% to 90% (RH), noncondensing short-
term (< 1% of operational hour per year)
Storage temperature 40°-70°C (40° to 158°F) 40°-70°C (40° to 158°F)
Storage humidity 5% to 90% (RH), noncondensing 5% to 90% (RH), noncondensing
8 Introduction