Setup Guide

62 Dell EMC PowerEdge MX SmartFabric Configuration and Troubleshooting Guide
Version : 1.0
Local System MAC address : 20:04:0f:00:b8:1e
VLT MAC address : 20:04:0f:00:b8:1e
IP address : fda5:74c8:b79e:1::1
Delay-Restore timer : 90 seconds
Peer-Routing : Disabled
Peer-Routing-Timeout timer : 0 seconds
VLTi Link Status
port-channel1000 : up
VLT Peer Unit ID System MAC Address Status IP Address Version
--------------------------------------------------------------------------------
2 20:04:0f:00:9d:1e up fda5:74c8:b79e:1::2 1.0
8.4.9 show vlt domain-id vlt-port-detail
The show vlt domain-id vlt-port-detail command shows the VLT port channel status for both
VLT peers. The VLT in this example is connected to the Cisco ACI vPC. It is automatically configured in port
channel 1, and it consists of two ports on each switch.
MX9116n-1# show vlt 255 vlt-port-detail
vlt-port-channel ID : 1
VLT Unit ID Port-Channel Status Configured ports Active ports
-------------------------------------------------------------------------------
* 1 port-channel1 up 2 2
2 port-channel1 up 2 2
8.4.10 show interface port channel summary
The show interface port-channel summary command shows the LAG number (VLT port
channel 1 in this example), the mode, status and ports used in the port channel.
MX9116n-1# show interface port-channel summary
LAG Mode Status Uptime Ports
1 L2-HYBRID up 00:29:20 Eth 1/1/43 (Up)
Eth 1/1/44 (Up)