Users Guide

Table Of Contents
No Fabric found for specified nodes. Please recheck and issue this command again.
Output example when you use the module replacement command in the master IOM:
admin@MX9116N-A2:~$ sfs_node_replace.py JDB1XC2 68RRNK2
Enter the Username for the Admin: admin
Password:
% Total % Received % Xferd Average Speed Time Time Time Current
Dload Upload Total Spent Left Speed
100 142 100 89 100 53 646 384 --:--:-- --:--:-- --:--:-- 649
Node replacement work-flow is initiated, the node JDB1XC2 will reboot into Fabric mode.
After successful authentication, the system initiates the module replacement workflow and the new IOM reboots and is placed in the
SmartFabric Services mode.
Connect the new IOM
After the switch reboots to the SmartFabric Services mode, connect all the cables as originally connected to the failed IOM.
PowerEdge MX Ethernet I/O modules 293